Comparison of laser surface scanning and fiducial marker-based registration in frameless stereotaxy. Technical note.

نویسندگان

  • Kurt Schicho
  • Michael Figl
  • Rudolf Seemann
  • Markus Donat
  • Michael L Pretterklieber
  • Wolfgang Birkfellner
  • Astrid Reichwein
  • Felix Wanschitz
  • Franz Kainberger
  • Helmar Bergmann
  • Arne Wagner
  • Rolf Ewers
چکیده

The authors compared the accuracy of laser surface scanning patient registration using the commercially available Fazer (Medtronic, Inc.) with the conventional registration procedure based on fiducial markers (FMs) in computer-assisted surgery. Four anatomical head specimens were prepared with 10 titanium microscrews placed at defined locations and scanned with a 16-slice spiral computed tomography unit. To compare the two registration methods, each method was applied five times for each cadaveric specimen; thus data were obtained from 40 registrations. Five microscrews (selected following a randomization protocol) were used for each FM-based registration; the other five FMs were selected for coordinate measurements by touching with a point measurement stylus. Coordinates of these points were also measured manually on the screen of the navigation computer. Coordinates were measured in the same manner after laser surface registration. The root mean square error as calculated by the navigation system ranged from 1.3 to 3.2 mm (mean 1.8 mm) with the Fazer and from 0.3 to 1.8 mm (mean 1.0 mm) with FM-based registration. The overall mean deviations (the arithmetic mean of the mean deviations of measurements on the four specimens) were 3.0 mm (standard deviation [SD] range 1.4-2.6 mm) with the Fazer and 1.4 mm (SD range 0.4-0.9 mm) with the FMs. The Fazer registration scans 300 surface points. Statistical tests showed the difference in the accuracy of these methods to be highly significant. In accordance with the findings of other groups, the authors concluded that the inclusion of a larger number of registration points might improve the accuracy of Fazer registration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monocular Visual Patient Monitoring for Frameless Stereotaxy

In this paper, we propose a low cost, robust vision based system for monitoring patient movements during stereotactic radiotherapy: the Monocular Visual Patient Movement Monitoring (MVPM) System. The system consists of a light weight mouth bite with dual fiducial system used for position tracking. One set of fiducials consist of easy-to-detect checkerboard whose 3D position can be tracked using...

متن کامل

Frameless robotic stereotactic biopsies: a consecutive series of 100 cases.

OBJECT Stereotactic biopsy procedures are an everyday part of neurosurgery. The procedure provides an accurate histological diagnosis with the least possible morbidity. Robotic stereotactic biopsy needs to be an accurate, safe, frameless, and rapid technique. This article reports the clinical results of a series of 100 frameless robotic biopsies using a Medtech ROSA device. METHODS The author...

متن کامل

Study on the clinical application of pulsed DC magnetic technology for tracking of intraoperative head motion during frameless stereotaxy

BACKGROUND Tracking of post-registration head motion is one of the major problems in frameless stereotaxy. Various attempts in detecting and compensating for this phenomenon rely on a fixed reference device rigidly attached to the patient's head. However, most of such reference tools are either based on an invasive fixation technique or have physical limitations which allow mobility of the head...

متن کامل

Principles of Neuronavigation

Background and Aim: Numerous efforts over the past century have been performed. Various innovation techniques are increasingly gaining attention and gradually established the foundation of recent significant developments in the world of neurosurgery, among which varied stereotactic neuro-navigation designs and other novel emerging systems are being quotidian developed. This narrative review ai...

متن کامل

Ultrasound A - Mode Based Registration in Computer Aided Surgery of the Skull

Objective: To evaluate the integration of ultrasound Amplitude (A)-mode based surface matching for non-invasive registration of the head into a frameless computer aided surgery system for Oto-Rhinology and Skull Base Surgery, and its accuracy. Design: Experimental study and case series. Setting: Academic medical center. Patients: Twelve patients underwent anterior/para-nasal skull base surgery ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of neurosurgery

دوره 106 4  شماره 

صفحات  -

تاریخ انتشار 2007