Design and analysis of electrically calibrated tympanic thermometers.
نویسندگان
چکیده
A new tympanic thermometer is analyzed and testedexperimentally. An electrically calibrated pyroelectric detector ofspecial configuration is employed to determine a person's bodytemperature. An energy-storage, power-supply-isolated capacitor isused as the electrical heating reference. The new thermometerdesign has an accuracy within ?0.1 degrees C with a 90% confidence and isimmune to ambient temperature, detector aging, and parametervariations. An equivalent-circuit model is established in theanalysis to account for the heat exchanges among the tympanum, thesurroundings, and the detector as well as for the electrothermalbehavior of the detector. The model provides effective simulationof the thermometer with PSPICE. Critical parameters governing theaccuracy and the limitation of the tympanic thermometer are alsopointed out by the simulation.
منابع مشابه
Reviewing the effectiveness of tympanic thermometers.
Tympanic thermometers have become a popular alternative to glass mercury thermometers for recording patients' temperatures. This article reviews studies that have been performed to audit their use in clinical practice. It examines the accuracy of tympanic thermometers and discusses ways to improve the use of this instrument and the implications for nursing practice.
متن کاملAccuracy of a noninvasive temporal artery thermometer for use in infants.
OBJECTIVES To assess the accuracy of a new noninvasive temporal artery (TA) thermometer in infants; to compare the accuracy of the TA thermometer with that of a tympanic thermometer, using rectal thermometry as the criterion standard; and to compare the tolerability of the TA thermometer with that of the tympanic and rectal thermometers. DESIGN Prospective evaluation of the accuracy of TA and...
متن کاملTympanic versus rectal thermometry in pregnant women.
OBJECTIVE To assess the accuracy of the tympanic membrane thermometer for use with pregnant women. DESIGN Cross-sectional descriptive study. SETTING A major medical center in the midwestern United States. PARTICIPANTS Thirty-three hospitalized, afebrile pregnant women. MAIN OUTCOME MEASURES Tympanic membrane thermometers and glass mercury thermometers were used to measure body temperatu...
متن کاملComparison of oral and tympanic temperatures in adult surgical patients.
Monitoring patients' temperatures is an important aspect of clinical nursing. In surgical areas, we rely on accurate temperature readings to determine appropriate therapy. Various body sites have been used for temperature measurement: oral, axillary, rectal, and tympanic. Oral temperature readings have long been considered the gold standard. However, oral temperature readings may be contraindic...
متن کاملEvaluation of Performance and Uncertainty of Infrared Tympanic Thermometers
Infrared tympanic thermometers (ITTs) are easy to use and have a quick response time. They are widely used for temperature measurement of the human body. The accuracy and uncertainty of measurement is the importance performance indicator for these meters. The performance of two infrared tympanic thermometers, Braun THT-3020 and OMRON MC-510, were evaluated in this study. The cell of a temperatu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied optics
دوره 37 13 شماره
صفحات -
تاریخ انتشار 1998