Management of Prolonged Pulmonary Air Leaks With Endobronchial Valve Placement

نویسندگان

  • Charles Bakhos
  • Peter Doelken
  • Stevan Pupovac
  • Ashar Ata
  • Tom Fabian
چکیده

BACKGROUND Prolonged pulmonary air leaks (PALs) are associated with increased morbidity and extended hospital stay. We sought to investigate the role of bronchoscopic placement of 1-way valves in treating this condition. METHODS We queried a prospectively maintained database of patients with PAL lasting more than 7 days at a tertiary medical center. Main outcome measures included duration of chest tube placement and hospital stay before and after valve deployment. RESULTS Sixteen patients were eligible to be enrolled from September 2012 through December 2014. One patient refused to give consent, and in 4 patients, the source of air leak could not be identified with bronchoscopic balloon occlusion. Eleven patients (9 men; mean age, 65 ± 15 years) underwent bronchoscopic valve deployment. Eight patients had postoperative PAL and 3 had a secondary spontaneous pneumothorax. The mean duration of air leak before valve deployment was 16 ± 12 days, and the mean number of implanted valves was 1.9 (median, 2). Mean duration of hospital stay before and after valve deployment was 18 and 9 days, respectively (P = .03). Patients who had more than a 50% decrease in air leak on digital monitoring had the thoracostomy tube removed within 3-6 days. There were no procedural complications related to deployment or removal of the valves. CONCLUSIONS Bronchoscopic placement of 1-way valves is a safe procedure that could help manage patients with prolonged PAL. A prospective randomized trial with cost-efficiency analysis is necessary to better define the role of this bronchoscopic intervention and demonstrate its effect on air leak duration.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Successful treatment of persistent postoperative air leaks following the placement of an endobronchial one-way valve.

Treatment of persistent air leaks due to pulmonary resection in pathological conditions of the lung involve a very large spectrum of available methods, from chest drainage and placement of Heimlich valves to surgical repair or pleural decortication. However, in some of these patients surgery may be contraindicated. This report describes an endobronchial approach to the control of marked and pro...

متن کامل

Bronchopleural Fistula Resolution with Endobronchial Valve Placement and Liberation from Mechanical Ventilation in Acute Respiratory Distress Syndrome: A Case Series

Patients who have acute respiratory distress syndrome (ARDS) with persistent air leaks have worse outcomes. Endobronchial valves (EBV) are frequently deployed after pulmonary resection in noncritically ill patients to reduce and eliminate bronchopleural fistulas (BPFs) with persistent air leak (PAL). Information regarding EBV placement in mechanically ventilated patients with ARDS and high volu...

متن کامل

Endobronchial valve placement for intractable airleaks

Background/Introduction Prolonged alveolo-pleural and broncho-pleural airleaks can be vexing problems for Thoracic Surgeons and arise after pulmonary procedures or spontaneously: often in the setting of underlying lung disease or infection. Patients with debilitation, HIV infection, end stage lung disease or following lung transplantation may be poor candidates for surgical intervention. Bronch...

متن کامل

Endoscopic treatment of persistent alveolar-pleural air leaks with a unidirectional endobronchial valve.

The persistent air leaks due to alveolopleural fistula are not an uncommon complication of pneumothorax, particularly secondary ones. Unidirectional flow endobronchial valves designed for lung volume reduction are the latest incorporation to the therapeutic armamentarium. We present the case of a patient with chronic obstructive pulmonary disease (COPD) with persistent pneumothorax in spite of ...

متن کامل

Endobronchial one-way valves for treatment of persistent air leaks: a systematic review

Persistent air leak (PAL) is associated with significant morbidity and mortality, prolonged hospitalization and increased health-care costs. It can arise from a number of conditions, including pneumothorax, necrotizing infection, trauma, malignancies, procedural interventions and complications after thoracic surgery. Numerous therapeutic options, including noninvasive and invasive techniques, a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 20  شماره 

صفحات  -

تاریخ انتشار 2016