Semi-automatic determination of lead in whole blood.

نویسندگان

  • H T Delves
  • P Vinter
چکیده

The procedure developed by Browett and Moss (1964) for the semi-automatic determination of the lead content of urine has been adapted for the determination of lead in blood. Determinations are normally carried out in duplicate on 2.0 ml. samples of whole blood and the minimum sample size is 0.5 ml. The organic substances present in blood are destroyed by a manual wet-oxidation procedure and the lead is determined colorimetrically as lead dithizonate using a Technicon AutoAnalyzer. The lower limit of detection, expressed as three times the standard deviation of the blank value, is 5 mug. Pb/100 ml. blood. The standard deviation of the method in the upper range of normal blood lead level of 30 mug. Pb/100 ml. blood (Moncrieff, Koumides, Clayton, Patrick, Renwick, and Roberts, 1964), is +/- 3 mug. Pb/100 ml. blood. Ten samples per hour may be estimated in duplicate.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stereospecific Determination of Mefloquine in Whole Blood by HPLC

Mefloquine, as a racemic mixture, is used for the treatment and prophylaxis of malaria. Stereoselective pharmacodynamic and pharmacokinetic differences has been observed for mefloquine. In this study a modified stereoselective HPLC method is presented for determination of mefloquine (MFQ) enantiomers in whole blood. The assay involved liquid-liquid extraction of MFQ from biological fluids with ...

متن کامل

Effects of pre-analytical handling on selected canine hematological parameters evaluated by automatic analyzer

To assess the effects of pre-analytical handling (storage time and temperature) on selected hematological parameters, whole blood samples were collected in EDTA coated tubes from each of 30 clinically normal male adult beagle dogs. Each sample was separated in 2 aliquots, of which one was stored in ambient temperature (25 ˚C) and the other one was refrigerated (2 to 4 ˚C). Complete blood counts...

متن کامل

Studying Changes of the Effective Radius in Blood Vessels after Exposure of Lower Extremities to Periodical Mechanical Vibrations

Background: Previous studies demonstrated a health improving effect in patients underwent an automatic vibratory massage taking 10 minutes. One of reasons that may explain a healing effect of the automatic massage is a stimulated increase in both blood circulation through vascular system and effective size of blood vessels. Objective: This paper aims to quantify a contribution of the auto...

متن کامل

Association of the whole blood potassium polymorphism with resistant to saline in two sheep breeds of different climates of Iran

Abstract The whole blood potassium concentration has shown the bimodal distribution in sheep, which has been classified into LK and HK types; HK allele is recessive to LK with a single gene inheritance. This polymorphism showed different behavior in different environment, which could be due to adaptation process. This research was conducted on the Zel and kermani breed research station, which...

متن کامل

Direct determination of cadmium and lead in whole blood by potentiometric stripping analysis.

The commercially available equipment for potentiometric stripping analysis (PSA) was tested for routine lead and cadmium determination in whole-blood samples. In contrast to anodic stripping voltammetry, PSA is not subject to background interferences from organic electroactive constituents in the sample or to the presence of dissolved oxygen (i.e., oxygen removal is not necessary). To determine...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 19 5  شماره 

صفحات  -

تاریخ انتشار 1966