Design and Fabrication of a Precision Alignment System and Package for a Two - Photon Fluorescence Imaging
نویسنده
چکیده
A compact, lightweight precision alignment system and package for an endomicroscope was designed and fabricated. The endomicroscope will consist of a millimeter-scale fiber resonator and a two-axis silicon optical bench. The alignment system provided five degrees of freedom and was designed to align the fiber resonator with the microchip with a resolution of one micron. The alignment system consisted of a system of ultra-fine screws and two compliant mechanisms to deamplify the motion of the screw. Finite element analysis was performed to optimize the compliant mechanisms for the desired transmission ratio of 20:1. The alignment system was fabricated and testing showed that the transmission ratios were lower than expected (18.6 for one compliant mechanism and 2.68 for the other). Testing also showed that the alignment system met the functional requirements for the ranges of motion. Thesis Supervisor: Martin L. Culpepper Title: Associate Professor of Mechanical Engineering
منابع مشابه
Design and Fabrication Process of MTF Phantom CT Scan
Introduction: One of the main steps in the optimization process in diagnostic imaging is the quality control of radiology devices. The usual method of CT scan calibration is used of a phantom. The phantom created a certain weakening for the radiation through which it passes. One of the most suitable methods for quantitative analysis of the resolution and contrast in CT scan im...
متن کاملDesign and Fabrication of the Mechanical Part of a Prototype Multileaf Collimator System
Introduction: Multileaf collimator (MLC) is state of the art among the radiation field shaping systems for conformal radiotherapy techniques. Some advantages of this system are as follow: reduction of treatment time, higher precision in conforming the radiation field to the projection of the target volume and lowering the chance of errors made by technologists. The purpose of this research was ...
متن کاملFabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System
Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in...
متن کاملFabrication of anthropomorphic phantoms for use in total body photon irradiation and total skin electron irradiation studies
Introduction: Total Skin Electron Therapy (TSET) and Total Body Irradiation (TBI) are kinds of treatment which use electron and photon beams to treat special types of cancers. The aim of these techniques are to deliver uniform dose to the entire skin while minimizing delivered dose to organs at risk. To check the homogeneity of dose delivery in TBI and TSET, using a humanoid ph...
متن کاملEvaluation of performance quality of SPECT camera in Shariati Hospital of Tehran University of Medical Sciences [Persian]
In nuclear medicine, there are two methods of imaging, planar and tomography. Single photon emission computerized tomography (SPECT) shows better image details and therefore is influenced more by image parameters such as resolution, uniformity, sensitivity, etc. Manufacturers provide customers with data which are obtained by complicated and sometimes secret methods. Marketing companies te...
متن کامل