Single breath-hold assessment of cardiac function using an accelerated 3D single breath-hold acquisition technique - comparison of an intravascular and extravascular contrast agent

نویسندگان

  • Marcus R Makowski
  • Andrea J Wiethoff
  • Christian HP Jansen
  • Sergio Uribe
  • Victoria Parish
  • Andreas Schuster
  • Rene M Botnar
  • Aaron Bell
  • Christoph Kiesewetter
  • Reza Razavi
  • Tobias Schaeffter
  • Gerald F Greil
چکیده

BACKGROUND Cardiovascular magnetic resonance (CMR) is the current gold standard for the assessment of left ventricular (LV) function. Repeated breath-holds are needed for standard multi-slice 2D cine steady-state free precession sequences (M2D-SSFP). Accelerated single breath-hold techniques suffer from low contrast between blood pool and myocardium. In this study an intravascular contrast agent was prospectively compared to an extravascular contrast agent for the assessment of LV function using a single-breath-hold 3D-whole-heart cine SSFP sequence (3D-SSFP). METHODS LV function was assessed in fourteen patients on a 1.5 T MR-scanner (Philips Healthcare) using 32-channel coil technology. Patients were investigated twice using a 3D-SSFP sequence (acquisition time 18-25 s) after Gadopentetate dimeglumine (GdD, day 1) and Gadofosveset trisodium (GdT, day 2) administration. Image acquisition was accelerated using sensitivity encoding in both phase encoding directions (4xSENSE). CNR and BMC were both measured between blood and myocardium. The CNR incorporated noise measurements, while the BMC represented the coeffiancy between the signal from blood and myocardium [1]. Contrast to noise ratio (CNR), blood to myocardium contrast (BMC), image quality, LV functional parameters and intra-/interobserver variability were compared. A M2D-SSFP sequence was used as a reference standard on both days. RESULTS All 3D-SSFP sequences were successfully acquired within one breath-hold after GdD and GdT administration. CNR and BMC were significantly (p < 0.05) higher using GdT compared to GdD, resulting in an improved endocardial definition. Using 3D-SSFP with GdT, Bland-Altman plots showed a smaller bias (95% confidence interval LVEF: 9.0 vs. 23.7) and regression analysis showed a stronger correlation to the reference standard (R2 = 0.92 vs. R2 = 0.71), compared to 3D-SSFP with GdD. CONCLUSIONS A single-breath-hold 3D-whole-heart cine SSFP sequence in combination with 32-channel technology and an intravascular contrast agent allows for the accurate and fast assessment of LV function.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accurate assessment of ventricular volumes in a single breath hold using a 32-channel coil and an extracellular contrast agent

Introduction: Functional assessment of cardiac ventricles is an essential aspect of cardiac MR. It provides regional wall motion abnormalities and volumetric data which are important clinical measures. Traditionally cine images are acquired in the short axis (SA) orientation with multiple slices through the ventricles. Although well validated one draw back of this technique is that the multiple...

متن کامل

3D late gadolinium enhancement in a single prolonged breath-hold using supplemental oxygenation and hyperventilation.

PURPOSE To evaluate the feasibility of three-dimensional (3D) single breath-hold late gadolinium enhancement (LGE) of the left ventricle (LV) using supplemental oxygen and hyperventilation and compressed-sensing acceleration. METHODS Breath-hold metrics [breath-hold duration, diaphragmatic/LV position drift, and maximum variation of R wave to R wave (RR) interval] without and with supplementa...

متن کامل

Fast 3D cine steady-state free precession imaging with sensitivity encoding for assessment of left ventricular function in a single breath-hold.

OBJECTIVE This study compares single breath-hold 3D cine steady-state free precession (SSFP) MRI using sensitivity encoding (SENSE) with standard 2D cine SSFP imaging in the quantitative evaluation of global left ventricular (LV) function. MATERIALS AND METHODS The LV function of 22 healthy volunteers and 15 patients was evaluated using a standard 2D SSFP sequence and a 3D SSFP sequence with ...

متن کامل

Optimization of single shot 3D breath-hold non-enhanced MR angiography of the renal arteries

BACKGROUND Cardiac and navigator-gated, inversion-prepared non-enhanced magnetic resonance angiography techniques can accurately depict the renal arteries without the need for contrast administration. However, the scan time and effectiveness of navigator-gated techniques depend on the subject respiratory pattern, which at times results in excessively prolonged scan times or suboptimal image qua...

متن کامل

Magnetic resonance assessment of left ventricular volumes and mass using a single-breath-hold 3D k-t BLAST cine b-SSFP in comparison with multiple-breath-hold 2D cine b-SSFP

OBJECTIVE To assess the feasibility of single-breath-hold three-dimensional cine b-SSFP (balanced steady-state free precession gradient echo) sequence (3D-cine), accelerated with k-t BLAST (broad-use linear acquisition speed-up technique), compared with multiple-breath-hold 2D cine b-SSFP (2D-cine) sequence for assessment of left ventricular (LV) function. METHODS Imaging was performed using ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2012