Double-barreled and Concentric Microelectrodes for Measurement of Extracellular Ion Signals in Brain Tissue.

نویسندگان

  • Nicole Haack
  • Simone Durry
  • Karl W Kafitz
  • Mitchell Chesler
  • Christine Rose
چکیده

Electrical activity in the brain is accompanied by significant ion fluxes across membranes, resulting in complex changes in the extracellular concentration of all major ions. As these ion shifts bear significant functional consequences, their quantitative determination is often required to understand the function and dysfunction of neural networks under physiological and pathophysiological conditions. In the present study, we demonstrate the fabrication and calibration of double-barreled ion-selective microelectrodes, which have proven to be excellent tools for such measurements in brain tissue. Moreover, so-called "concentric" ion-selective microelectrodes are also described, which, based on their different design, offer a far better temporal resolution of fast ion changes. We then show how these electrodes can be employed in acute brain slice preparations of the mouse hippocampus. Using double-barreled, potassium-selective microelectrodes, changes in the extracellular potassium concentration ([K+]o) in response to exogenous application of glutamate receptor agonists or during epileptiform activity are demonstrated. Furthermore, we illustrate the response characteristics of sodium-sensitive, double-barreled and concentric electrodes and compare their detection of changes in the extracellular sodium concentration ([Na+]o) evoked by bath or pressure application of drugs. These measurements show that while response amplitudes are similar, the concentric sodium microelectrodes display a superior signal-to-noise ratio and response time as compared to the double-barreled design. Generally, the demonstrated procedures will be easily transferable to measurement of other ions species, including pH or calcium, and will also be applicable to other preparations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous Measurement of Intracellular pH and K+ or NO3- in Barley Root Cells Using Triple-Barreled, Ion-Selective Microelectrodes.

The manufacture and use of triple-barreled microelectrodes, which are capable of simultaneous in vivo measurement of intracellular pH and the activities of K+ or NO3- and cell membrane potential (Em), are described. Scanning electron micrographs showed that the three tips were aligned and that the overall tip diameter was approximately 0.8 [mu]m. When filled with 100 mM KCl, all three barrels s...

متن کامل

Fabrication and Use of High-Speed, Concentric H - and Ca -Selective Microelectrodes Suitable for In Vitro Extracellular Recording

Fedirko, Nataliya, Nataliya Svichar, and Mitchell Chesler. Fabrication and use of high-speed, concentric H and Ca -selective microelectrodes suitable for in vitro extracellular recording. J Neurophysiol 96: 919–924, 2006; doi:10.1152/jn.00258.2006. Ion-selective microelectrodes (ISMs) have been used extensively in neurophysiological studies. ISMs selective for H and Ca are notable for their sen...

متن کامل

Innovative Methodology Fabrication and Use of High-Speed, Concentric H - and Ca -Selective Microelectrodes Suitable for In Vitro Extracellular Recording

Fedirko, Nataliya, Nataliya Svichar, and Mitchell Chesler. Fabrication and use of high-speed, concentric H and Ca -selective microelectrodes suitable for in vitro extracellular recording. J Neurophysiol 96: 919–924, 2006; doi:10.1152/jn.00258.2006. Ion-selective microelectrodes (ISMs) have been used extensively in neurophysiological studies. ISMs selective for H and Ca are notable for their sen...

متن کامل

Phasic Oscillations of Extracellular Potassium (Ko) in Pregnant Rat Myometrium

K-sensitive microelectrodes were used to measure K(+) within the extracellular space (K(o)) of pregnant rat myometrium. Contractile activity was monitored by measuring either force or bioelectrical signals. Single and double-barreled electrodes were used. Double-barreled electrodes allowed monitoring of electrical activity 15 microns from the site of K(o) measurement. From double-barreled elect...

متن کامل

Fabrication and use of high-speed, concentric h+- and Ca2+-selective microelectrodes suitable for in vitro extracellular recording.

Ion-selective microelectrodes (ISMs) have been used extensively in neurophysiological studies. ISMs selective for H(+) and Ca(2+) are notable for their sensitivity and selectivity, but suffer from a slow response time, and susceptibility to noise because of the high electrical resistance of the respective ion exchange cocktails. These drawbacks can be overcome by using a "coaxial" or "concentri...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of visualized experiments : JoVE

دوره 103  شماره 

صفحات  -

تاریخ انتشار 2015