4-D micro-CT of the mouse heart.

نویسندگان

  • Cristian T Badea
  • Boma Fubara
  • Laurence W Hedlund
  • G Allan Johnson
چکیده

PURPOSE Demonstrate noninvasive imaging methods for in vivo characterization of cardiac structure and function in mice using a micro-CT system that provides high photon fluence rate and integrated motion control. MATERIALS AND METHODS Simultaneous cardiac- and respiratory-gated micro-CT was performed in C57BL/6 mice during constant intravenous infusion of a conventional iodinated contrast agent (Isovue-370), and after a single intravenous injection of a blood pool contrast agent (Fenestra VC). Multiple phases of the cardiac cycle were reconstructed with contrast to noise and spatial resolution sufficient for quantitative assessment of cardiac function. RESULTS Contrast enhancement with Isovue-370 increased over time with a maximum of approximately 500 HU (aorta) and 900 HU (kidney cortex). Fenestra VC provided more constant enhancement over 3 hr, with maximum enhancement of approximately 620 HU (aorta) and approximately 90 HU (kidney cortex). The maximum enhancement difference between blood and myocardium in the heart was approximately 250 HU for Isovue-370 and approximately 500 HU for Fenestra VC. In mice with Fenestra VC, volumetric measurements of the left ventricle were performed and cardiac function was estimated by ejection fraction, stroke volume, and cardiac output. CONCLUSION Image quality with Fenestra VC was sufficient for morphological and functional studies required for a standardized method of cardiac phenotyping of the mouse.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantification of periapical bone destruction in mice by micro-computed tomography.

Bacterial infections of the dental pulp result in tissue destruction and periapical bone resorption. The availability of genetically engineered mouse strains is a major advantage in the use of this model system for studies of periapical pathogenesis. The main limitation of the mouse model is its small size, and the necessity for laborious histologic analyses to quantify periapical bone destruct...

متن کامل

Rapid 3D phenotyping of cardiovascular development in mouse embryos by micro-CT with iodine staining.

BACKGROUND Microcomputed tomography (micro-CT) has been used extensively in research to generate high-resolution 3D images of calcified tissues in small animals nondestructively. It has been especially useful for the characterization of skeletal mutations but limited in its utility for the analysis of soft tissue such as the cardiovascular system. Visualization of the cardiovascular system has ...

متن کامل

P-54: Toxic effect of Carthamus Tinctorius L.(Safflower) Extract in the Mouse Testis

Background: Natural products of plant origin are still a major part of traditional medicinal systems in many countries. Carthamus tinctorius L. (CT), also named safflower, is one of the popular herbs traditionally consumed raw amongst people in Iran. The main objective of the present study was to investigate the effects of aqueous extract of CT on the mouse testis. Materials and Methods: Experi...

متن کامل

A Novel Mouse Segmentation Method Based on Dynamic Contrast Enhanced Micro-CT Images

With the development of hybrid imaging scanners, micro-CT is widely used in locating abnormalities, studying drug metabolism, and providing structural priors to aid image reconstruction in functional imaging. Due to the low contrast of soft tissues, segmentation of soft tissue organs from mouse micro-CT images is a challenging problem. In this paper, we propose a mouse segmentation scheme based...

متن کامل

An Estimation of Multiphase Relative Permeabilities in Reservoir Cores from Micro-CT Data

With significant increase of tomographic equipment power, demand for Prediction relative permeability prediction Predicting in porous media from digital image data. In this work, it is predicted three -phase relative permeabilities with co-applying Darcy’s and Stokes equations in two case studies, namely Bentheimer sandstone and Estaillades limestone which their micro-CT data files were downloa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Molecular imaging

دوره 4 2  شماره 

صفحات  -

تاریخ انتشار 2005