Inert gas clearance from tissue by co-currently and counter-currently arranged microvessels.
نویسندگان
چکیده
To elucidate the clearance of dissolved inert gas from tissues, we have developed numerical models of gas transport in a cylindrical block of tissue supplied by one or two capillaries. With two capillaries, attention is given to the effects of co-current and counter-current flow on tissue gas clearance. Clearance by counter-current flow is compared with clearance by a single capillary or by two co-currently arranged capillaries. Effects of the blood velocity, solubility, and diffusivity of the gas in the tissue are investigated using parameters with physiological values. It is found that under the conditions investigated, almost identical clearances are achieved by a single capillary as by a co-current pair when the total flow per tissue volume in each unit is the same (i.e., flow velocity in the single capillary is twice that in each co-current vessel). For both co-current and counter-current arrangements, approximate linear relations exist between the tissue gas clearance rate and tissue blood perfusion rate. However, the counter-current arrangement of capillaries results in less-efficient clearance of the inert gas from tissues. Furthermore, this difference in efficiency increases at higher blood flow rates. At a given blood flow, the simple conduction-capacitance model, which has been used to estimate tissue blood perfusion rate from inert gas clearance, underestimates gas clearance rates predicted by the numerical models for single vessel or for two vessels with co-current flow. This difference is accounted for in discussion, which also considers the choice of parameters and possible effects of microvascular architecture on the interpretation of tissue inert gas clearance.
منابع مشابه
COUPLING MODEL FOR MULTI-COMPONENT GAS PERMEATION PROCESS
A gas permeation model (Coupling Model) has been developed which has the flexibility to be used for different membrane module configurations. The aim of this work is to predict the performance of a single stage gas separation process using membranes and provide a comprehensive description of process parameters like flow rates, composition, stage cut and stream pressure. The significant feature ...
متن کاملInert gas diffusion method for measurement of blood flow using saturation techniques. Comparison with directly measured blood flow in isolated gastrocnemius muscle of the cat.
The isolated gastrocnemius muscle of the cat was used to study the relation between the desaturation of xenon measured by external monitoring, and blood flow measured directly by a dropcounter. The metered blood flow agreed with that calculated from the initial slope of the desaturation curve from tissue equilibrated by prolonged intra-arteria] infusion and also by atraumatic gas labelling of a...
متن کاملSpotlight: Organic salts: With Y-aromatic counter ions (Part II)
Meysam Yarie was born in 1987 in Malayer/ Hamedan, Iran. He received his B.Sc. in Applied Chemistry from Malek-Ashtar University of Technology and M.Sc. in Organic Chemistry from Kurdistan University under the supervision of Dr. Kamal Amani. He received his Ph.D. from Bu-Ali Sina University under the supervision of Professor Mohammad Ali Zolfigol. He is currently working towards his Post-Doctor...
متن کاملA method for determining inert gas ("N2") solubility in urine.
The present interest in the physiology of inert gases makes desirable a more accurate and reproducible method for determining the inert gas content of biological fluids than is currently available (2). This communication describes such a method. The method has been tested on water and used to determine the solubility of the inert gas of air in human urines of different solute concentrations at ...
متن کاملEffect of Nondimensional Parameters On the Internal Circulation of a Liquid Drop Moving with the Surrounding Gas
The internal flow circulation dynamics of a liquid drop moving in a co- or counter-flowing gas stream has been numerically studied. The present work is concerned with the time accurate numerical solution of the two phase flow field at the low Mach number limit with an appropriate volume tracking method to capture motion and deformation of a liquid drop. It is shown that relative velocity betwee...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of applied physiology
دوره 113 3 شماره
صفحات -
تاریخ انتشار 2012