Total bilirubin measurement by photometry on a blood gas analyzer: potential for use in neonatal testing at the point of care.

نویسندگان

  • B Rolinski
  • H Küster
  • B Ugele
  • R Gruber
  • K Horn
چکیده

The results are summarized in Table 1. The baseline absorbance of untreated plasma samples was significantly higher (0.106 6 0.076) than that of plasma samples treated with PEG (0.007 6 0.003; t 5 5.95; P ,0.001). There were no significant differences between the recovered ICG concentrations and the expected values at any of the four dye concentrations. Zweens and Frankena (4 ) demonstrated that the optimal concentration of PEG to eliminate baseline turbidity in plasma samples containing Evan’s blue dye was 240 g/L. In the present investigation involving ICG, we found that a PEG concentration of 240 g/L produced a 20% loss of the dye in the pellet. This finding is consistent with reports by Baker (1 ) and Kawasaki et al. (5 ), who demonstrated that a portion of ICG binds to non-albumin plasma proteins. A better PEG concentration for studies involving ICG was 120 g/L. This concentration produced the same beneficial reduction in the variable background absorbance as the higher concentrations but did not produce appreciable dye losses, and the recovery of ICG was nearly 100% across a range of typical ICG concentrations that are likely to be encountered in a patient study. Treatment of plasma samples with PEG may eliminate the need to perform separate calibration curves for each test subject. The standard protocol has been for participants to donate an initial blood sample that is used to develop an individual calibration curve. Individual curves have been necessary because the turbidity in the baseline plasma inflated the absorbance readings of subsequent samples. We have demonstrated that treating plasma samples with PEG effectively reduces the turbidity of plasma. Use of a common calibration curve to analyze plasma samples from more than one person is an appealing prospect because it can save time and reduce the volume of blood required to perform a study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Point-of-care determination of neonatal bilirubin with the blood gas analyzer RapidLab 1265.

BACKGROUND The aim of the study was to evaluate the comparability of the new neonatal bilirubin method on the RapidLab 1265 blood gas analyzer. This point-of-care testing (POCT) device has the option for the determination of neonatal bilirubin, making it potentially valuable for use in neonate intensive care units or in outpatient ambulances. METHODS We paired 240 patient samples for intermet...

متن کامل

The Value of Bilicheck® as a Screening Tool for Neonatal Jaundice in the South of Iran

The gold standard to assess jaundice in neonates is the serum bilirubin measurement. Blood sampling for the determination of total serum bilirubin (TSB) is painful for newborns and stressful for parents. The Bilicheck®, a new transcutaneous bilirubinometer, is considered as a more accurate measurement of bilirubin compared to the previous bilirubinometers courtesy of its advanced technology. Th...

متن کامل

Effect of hemolyzed plasma on the batch measurement of nitrate by nitric oxide chemiluminescence.

cepted reference method for total bilirubin determination is currently available. Thus, the widely used DPD procedure was chosen as the comparison method in this study. Quality specifications in terms of precision and accuracy met CLIA (11 ) as well as European regulatory requirements (12 ). In the patient samples, the measured bilirubin values covered the physiologically relevant range (85–400...

متن کامل

A Comparison between Transcutaneous Bilirubin (TcB) and Total Serum Bilirubin (TSB) Measurements in Term Neonates

Background: Transcutaneous bilirubinometry (TCB) is a simple method for estimating bilirubin levels in neonates. This method is noninvasive, quick, and painless. We aimed to compare serum and cutaneous bilirubin measurements in term neonates.Method: In this descriptive cross-sectional study, 200 neonates with icter with birth weights of at least 2500 grams were studied. TCB was measured using a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 47 10  شماره 

صفحات  -