Design criteria for multi-layered scintillating fibre arrays with inclined columns
نویسنده
چکیده
Multi-layered scintillating fibre arrays read-out are commonly used as high resolution charged particle hodoscopes. Fibres of a “column” along the geometrical trajectory of incident particles are typically grouped to one pixel of a multi-channel read-out device. In some applications the incident particles will cross the detection plane with large angles w.r.t. the normal to the layers. Then, the packing of the fibres needs to be adapted to the incident particles and the columns need to be inclined. In this paper possible fibre array geometries are shown, relevant design criteria for detectors are discussed, and the effect of diverging particles incident on fibre arrays was studied using a Monte Carlo simulation.
منابع مشابه
Response of Buildings with Inclined First-Story Columns to Near-Fault Ground Motion
In this paper a simple model of a three story building with inclined first-story columns has presented. The stories are supposed to be rigid and are connected to axially rigid mass less columns by elasto-plastic rotational springs and linear rotational dampers. The considered model is subjected to horizontal component of fault normal pulse with different magnitudes and the governed nonlinear di...
متن کاملDesign of Light Multi-layered Shields for Use in Diagnostic Radiology and Nuclear Medicine via MCNP5 Monte Carlo Code
Introduction Lead-based shields are the most widely used attenuators in X-ray and gamma ray fields. The heavy weight, toxicity and corrosion of lead have led researchers towards the development of non-lead shields. Materials and Methods The purpose of this study was to design multi-layered shields for protection against X-rays and gamma rays in diagnostic radiology and nuclear medicine. In this...
متن کاملDesign and Construction of a Scintillating Fibre Tracker for measuring Hard Exclusive Reactions at HERMES
Kenntnisse kann jedermann haben – aber die Kunst zu denken, ist das seltenste Geschenk der Natur. des Impulsübertrags verbessern kann.
متن کاملMeasuring Emittance with the Mice Scintillating Fibre Trackers
The Muon Ionization Cooling Experiment (MICE) aims to measure a 10% reduction in a muon beam emittance to within 1%. To achieve this two scintillating fibre trackers will be placed within a 4T solenoidal field. The trackers utilise fibres with a diameter of 350μm to provide a position resolution of less than 0.5mm. Details of the tracker hardware, electronics and its calibration and reconstruct...
متن کاملIn-beam tests of scintillating fibre detectors at MAMI and at GSI
The performance of scintillating fibre detectors was studied with electrons at the spectrometer facility of the Mainz microtron MAMI, as well as in a C beam of 2AGeV energy and in a beam of different particle species at GSI. Multi-anode photomultipliers were used to read out one or more bundles of 128 fibres each in different geometries. For electrons a time resolution of FWHM ∼ 1 ns was measur...
متن کامل