Modulation transfer function of a lens measured with a random target method.

نویسندگان

  • E Levy
  • D Peles
  • M Opher-Lipson
  • S G Lipson
چکیده

We measured the modulation transfer function (MTF) of a lens in the visible region using a random test target generated on a computer screen. This is a simple method to determine the entire MTF curve in one measurement. The lens was obscured by several masks so that the measurements could be compared with the theoretically calculated MTF. Excellent agreement was obtained. Measurement noise was reduced by use of a large number of targets generated on the screen.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Vehicle Interior Vibration Simulation-a Tool for Engine Mount Optimization

By new advancements in vehicle manufacturing vehicle quality evaluation and assurance has become a more critical issue. In present work, the vibration transfer path analysis and vibration path ranking of a car interior has been performed. The method is similar to classical multilevel TPA methods but has distinct differences. The method is named VIVS which stands for Vehicle Interior Vibratio...

متن کامل

Investigation of the Spatial Resolution of MR-Based Polymer Gel Dosimetry versus Film Densitometry using Dose Modulation Transfer Function

Introduction: The conventional methods of dosimetry are not capable of dosimetry in such a small volume of less than one cubic millimeter. Although the polymer gel dosimetry method based on magnetic resonance imaging (MRI) could achieve three dimensional dosimetry with high resolution, a spatial resolution evaluation based on gel dose modulation transfer function has not been investigated yet. ...

متن کامل

Defocusing Effect Studies in MTF of CCD Cameras Based on PSF Measuring Technique

Defocusing effects in modulation transfer function (MTF) measurement of charge coupled device (CCD) cameras is the main focus of current paper. We introduce measuring Point-spread function (PSF) in order to calculate the MTF and further more we will study the shape of MTF and its cut-off frequency by adjusting the lens focusing in different locations. A collimated white light LED by broadband s...

متن کامل

Design and Fabrication Process of MTF Phantom CT Scan

Introduction: One of the main steps in the optimization process in diagnostic imaging is the quality control of radiology devices. The usual method of CT scan calibration is used of a phantom. The phantom created a certain weakening for the radiation through which it passes. One of the most suitable methods for quantitative analysis of the resolution and contrast in CT scan im...

متن کامل

Optical characterization of ophthalmic lenses by means of modulation transfer function determination from a laser speckle pattern.

A method is presented for measuring the modulation transfer function of ophthalmic lenses by use of the generation of laser speckle with an integrating sphere. The measurements are performed with a rectangular double-slit aperture positioned at the output port of the integrating sphere. The distance between the lens and the detector determines the spatial frequency being tested; therefore high ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied optics

دوره 38 4  شماره 

صفحات  -

تاریخ انتشار 1999