Are the 10 Meter and 6 Minute Walk Tests Redundant in Patients with Spinal Cord Injury?
نویسندگان
چکیده
OBJECTIVE To evaluate the relationship and redundancy between gait speeds measured by the 10 Meter Walk Test (10MWT) and 6 Minute Walk Test (6MWT) after motor incomplete spinal cord injury (iSCI). To identify gait speed thresholds supporting functional ambulation as measured with the Spinal Cord Injury Functional Ambulation Inventory (SCI-FAI). DESIGN Prospective observational cohort. SETTING Seven outpatient rehabilitation centers from the Christopher and Dana Reeve Foundation NeuroRecovery Network (NRN). PARTICIPANTS 249 NRN patients with American Spinal Injury Association Impairment Scale (AIS) level C (n = 20), D (n = 179) and (n = 50) iSCI not AIS evaluated, from February 2008 through April 2011. INTERVENTIONS Locomotor training using body weight support and walking on a treadmill, overground and home/community practice. MAIN OUTCOME MEASURE(S) 10MWT and 6MWT collected at enrollment, approximately every 20 sessions, and upon discharge. RESULTS The 10MWT and 6MWT speeds were highly correlated and the 10MWT speeds were generally faster. However, the predicted 6MWT gait speed from the 10MWT, revealed increasing error with increased gait speed. Regression lines remained significantly different from lines of agreement, when the group was divided into fast (≥0.44 m/s) and slow walkers (<0.44 m/s). Significant differences between 6MWT and 10MWT gait speeds were observed across SCI-FAI walking mobility categories (Wilcoxon sign rank test p<.001), and mean speed thresholds for limited community ambulation differed for each measure. The smallest real difference for the 6MWT and 10MWT, as well as the minimally clinically important difference (MCID) values, were also distinct for the two tests. CONCLUSIONS While the speeds were correlated between the 6MWT and 10MWT, redundancy in the tests using predictive modeling was not observed. Different speed thresholds and separate MCIDs were defined for community ambulation for each test.
منابع مشابه
Step Activity Monitor: accuracy and test-retest reliability in persons with incomplete spinal cord injury.
Recovery of walking after incomplete spinal cord injury (iSCI) is a common focus of rehabilitation, but few measurement tools capture walking performance outside the clinic or laboratory. This study determined the accuracy and test-retest reliability of the Step Activity Monitor (SAM), a microprocessor-driven accelerometer that measures walking activity. We evaluated 11 individuals with iSCI du...
متن کاملStandardized assessment of walking capacity after spinal cord injury: the European network approach.
OBJECTIVES After a spinal cord injury (SCI), walking function is an important outcome measure for rehabilitation and new treatment interventions. The current status of four walking capacity tests that are applied to SCI subjects is presented: the revised walking index for spinal cord injury (WISCI II), the 6 minute walk test (6MinWT), 10 meter walk test (10MWT) and the timed up and go (TUG) tes...
متن کاملManagement of Hypotension and Bradycardia Caused by Spinal Cord Injury. The Usefulness of Midodrine and Methylxanthines
Spinal cord injury is a devastating chronic condition resulting in temporary or permanent motor,sensory or autonomic dysfunction of the cord. The manifestation of spinal cord injury based onthe severity and involved areas could be different. Numerous studies have demonstrated thatbradycardia, hypotension, and orthostatic hypotension are present insignificant number ofpat...
متن کاملManagement of Hypotension and Bradycardia Caused by Spinal Cord Injury. The Usefulness of Midodrine and Methylxanthines
Spinal cord injury is a devastating chronic condition resulting in temporary or permanent motor,sensory or autonomic dysfunction of the cord. The manifestation of spinal cord injury based onthe severity and involved areas could be different. Numerous studies have demonstrated thatbradycardia, hypotension, and orthostatic hypotension are present insignificant number ofpat...
متن کاملffectiveness of Automated Locomotor Training in Patients ith Chronic Incomplete Spinal Cord Injury: Multicenter Trial
Objective: To determine whether automated locomotor raining with a driven-gait orthosis (DGO) can increase funcional mobility in people with chronic, motor incomplete spinal ord injury (SCI). Design: Repeated assessment of the same patients or singlease experimental A-B design. Setting: Research units of rehabilitation hospitals in Chicago; eidelberg, Germany; and Basel and Zurich, Switzerland....
متن کامل