Incidence of visible and occult blood on laryngoscope blades and handles.

نویسندگان

  • R A Phillips
  • W P Monaghan
چکیده

Anesthesia providers must take appropriate precautions to reduce the potential for transmission of infectious agents to the patients under their care. The devastating spread of human immunodeficiency virus (HIV) and hepatitis B virus (HBV) over the past decade has resulted in the development of specific guidelines for the cleaning, disinfection, sterilization, and handling of medical equipment and instruments. Contamination of laryngoscope blades and handles with visible and occult blood frequently occurs during routine airway management. Several studies suggest procedures for cleaning, disinfection, sterilization, or handling of laryngoscope blades and handles are ineffective, or there may be poor compliance with the established protocols. The purpose of this study was to determine the incidence of visible and occult blood on laryngoscope blades and handles that were identified as ready for patient use. Sixty-five laryngoscope blades and handles identified as ready for patient use were observed for visible blood and tested for occult blood. A modified version of the three-stage phenolphthalein blood indicator test was employed to determine the presence of occult blood. None of the blades or handles observed had visible blood. Of the 65 blades tested for occult blood, 13 (20%) tested positive. Of the 65 handles tested for occult blood, 26 (40%) tested positive. More afternoon blades and handles tested positive for occult blood than morning blades and handles (P < 0.01). The extent to which contaminated anesthesia equipment plays in nosocomial infection is difficult to determine. The presence of blood is an indicator of potential cross-infection, since biological fluids, such as blood and saliva, are known to transmit infectious diseases. This study confirms that more rigorous decontamination protocols must be instituted to ensure complete removal of blood prior to sterilization, since laryngoscope blades and handles have irregular surfaces with repositories for infectious material.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Infection control practices of laryngoscope blades: a review of the literature.

Current procedures for cleaning anesthesia airway equipment as assessed by the presence of visible and occult blood on laryngoscope blades and handles as labeled "ready for patient use" has been reported to be ineffective. Human immunodeficiency virus (HIV) and the hepatitis B virus (HBV) are 2 commonly seen pathogens that frequently are found in the healthcare setting. It has been shown that H...

متن کامل

Contamination of laryngoscope handles.

Despite use of sterile or disposable laryngoscope blades for each patient, disinfection of laryngoscope handles does not routinely occur, and these devices present a potential route of transmission of pathogens between patients and staff. A total of 192 specimens from 64 laryngoscope handles deemed 'ready for patient use' in the anaesthetic rooms of 32 operating theatres were semiquantitatively...

متن کامل

Bacterial Contamination and Disinfection Status of Laryngoscopes Stored in Emergency Crash Carts

Objectives To identify bacterial contamination rates of laryngoscope blades and handles stored in emergency crash carts by hospital and area according to the frequency of intubation attempts. Methods One hundred forty-eight handles and 71 blades deemed ready for patient use from two tertiary hospitals were sampled with sterile swabs using a standardized rolling technique. Samples were conside...

متن کامل

Comparison of efficacy and cost-effectiveness of 0.55% ortho-phthalaldehyde and 2% glutaraldehyde for disinfection of laryngoscopes: A prospective pilot study

BACKGROUND AND AIMS The laryngoscope is a potential source of cross-infection as it involves contact with the mucous membrane, saliva and occasionally blood. This study compared efficacy and cost-effectiveness of two Centre for Disease Control approved agents for disinfection of laryngoscope blades. METHODS One hundred and sixty patients requiring laryngoscopy and intubation for general anaes...

متن کامل

Nosocomial contamination of laryngoscope handles: challenging current guidelines.

BACKGROUND Laryngoscope blades are often cleaned between cases according to well-defined protocols. However, despite evidence that laryngoscope handles could be a source of nosocomial infection, neither our institution nor the American Society of Anesthesiologists has any specific guidelines for handle disinfection. We hypothesized that laryngoscope handles may be sufficiently contaminated with...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AANA journal

دوره 65 3  شماره 

صفحات  -

تاریخ انتشار 1997