High 10-Year Survival Rate with an Anatomic Cementless Stem (SPS)
نویسندگان
چکیده
BACKGROUND Proximal cementless fixation using anatomic stems reportedly increases femoral fit and avoids stress-shielding. However, thigh pain was reported with the early stem designs. Therefore, a new anatomic cementless stem design was based on an average three-dimensional metaphyseal femoral shape. However, it is unclear whether this stem reduces the incidence of thigh pain. QUESTIONS/PURPOSES We asked whether this stem design was associated with a low incidence of thigh pain and provided durable fixation and high function. METHODS One hundred seventy-one patients (176 THAs) who had the anatomic proximal hydroxyapatite-coated stem implanted were reviewed. Eleven (6%) patients were lost to followup and 34 (20%) died without revision surgery. We used the Harris hip score (HHS) to assess pain and function. We evaluated femoral stem fixation and stability with the score of Engh et al. and also calculated a 10-year survival analysis. We assessed 126 patients (131 hips) at a mean followup of 10 years (range, 8-11 years) RESULTS At last followup, two patients described slight thigh pain that did not limit their physical activities. All stems appeared radiographically stable and one stem was graded nonintegrated but stable. Five patients had revision surgery: one on the femoral side (for posttraumatic fracture) and four on the acetabular side. Considering stem revision for aseptic loosening as the end point, survivorship was 100% (range, 95.4%-99.9%) at 10 years. CONCLUSION This anatomic cementless design using only metaphyseal fixation with a wide mediolateral flare, a sagittal curvature, and torsion, allowed durable proximal stem stability and fixation.
منابع مشابه
Results of 3,668 primary total hip replacements
BACKGROUND AND PURPOSE In a previous study based on the Finnish Arthroplasty Register, the survival of cementless stems was better than that of cemented stems in younger patients. However, the survival of cementless cups was poor due to osteolysis. In the present study, we analyzed population-based survival rates of the cemented and cementless total hip replacements in patients under the age of...
متن کاملTotal Hip Replacement Revision in a Single Brand Small Cementless Stem – Our Experience after the Findings of the National Joint Registry
Background: Cementless total hip replacement is the common THR performed in England, Wales, Northern Irelandand the Isle of Man. The Corail stem is the most popular cementless implant and has a ODEP 10A rating. Review ofits performance in the registry identified an increase rate of revision amongst the smaller stem sizes. However, claritywas not provided on the explanation for this finding. We ...
متن کاملCementless total hip arthroplasty for primary osteoarthritis in patients aged 55 years and older
BACKGROUND Cemented total hip arthroplasty has been the treatment of choice for elderly patients with osteoarthritis. We analyzed survival rates of the most common cementless designs used in this age group in Finland. PATIENTS AND METHODS Inclusion criteria permitted 10,310 replacements (8 designs) performed in patients aged 55 years or older to be selected for evaluation. The risk of revisio...
متن کامل19 years outcome after cementless total hip arthroplasty with spongy metal structured implants in patients younger than 65 years
BACKGROUND Cementless fixation of total hip arthroplasties (THAs) is often favored in young, high-demanding patients due to the conservation of valuable bone-stock and easier revision if loosening has occurred. Long-term outcome data of the spongy metal structured implant used in the present study in patients younger than 65 years are still lacking. METHODS We conducted a retrospective chart ...
متن کاملProspective five-year subsidence analysis of a cementless fully hydroxyapatite-coated femoral hip arthroplasty component.
Early subsidence >1.5 mm is considered to be a predictive factor for later aseptic loosening of the femoral component following total hip arthroplasty (THA). The aim of this study was to assess five-year subsidence rates of the cementless hydroxyapatite-coated twinSys stem (Mathys Ltd., Bettlach, Switzerland).This prospective single-surgeon series examined consecutive patients receiving a twinS...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 470 شماره
صفحات -
تاریخ انتشار 2012