The multiple indicator-dilution method for the study of enzyme heterogeneity in liver: theoretical basis.

نویسندگان

  • A J Schwab
  • K S Pang
چکیده

The theoretical basis of the use of the multiple indicator dilution technique to account for the heterogeneous distribution (or zonation) of enzymes in the liver was explored. The microcirculation was assumed to consist of identical capillaries perfused in parallel, with enzymatic activities for drug metabolism being distributed uniformly over the upstream half (periportal or pp) or the downstream half (perivenous or pv) of the flow path, whereas all other transport/removal processes were assumed to be homogeneously distributed. Outflow dilution profiles for parent drug and metabolite were estimated by inversion of Laplace transforms or by a finite difference method. The areas under the curves for parent and metabolite, the mean transit times of parent (MTT) and metabolite (MTTM, mean time from injection of parent to exit of metabolite from organ), and their relative dispersions (CV2 or CVM2) were estimated from analytical expressions. When the influx-efflux ratio (or cellular-sinusoidal distribution ratio) for metabolite was equal to or smaller than that of the parent, the MTTM ranking was: pp < homogeneous < pv. The ranking was reversed when the influx-efflux ratio for metabolite greatly exceeded that for the parent. The presence of elimination pathways for the metabolite reduced its MTTM and CVM2, more for pp than for homogeneous and pv cases. The theory can be applied to determine enzyme zonation in multiple indicator dilution studies with use of the area under the curve for the metabolite and MTTM during prograde (from portal vein to hepatic vein) and retrograde (from hepatic vein to portal vein) perfusion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of Triclabendazole on ALT Enzyme activity in Fasciola hepatica helminths and parasitized sheep liver tissues

Introduction: To determine an indicator for Triclabendazole (TCBZ) efficacy, Alanine aminotransferase (ALT) activity in Fasciola hepatica (Iranian isolate) parasite in presence and absence of TCBZ was evaluated by an in vitro cultivation method. Also, ALT enzyme activity between none and parasitized-infected sheep liver tissues was assessed. Method: &nbsp;The sheep livers were collected and tra...

متن کامل

بررسی فعالیت آنزیم‌های کبدی GGT،ALP،ALT،AST در سرم بیماران تحت جراحی سیستم عصبی قبل و پس از بیهوشی عمومی با داروی استنشاقی ایزوفلوران

 Background and Aim: Isoflurane is one of the selective and mostly-used respiratory anesthetic materials in the field of neurosurgery. Studies have shown that temporary rise in the level of liver enzymes may occur after anesthesia by halogenic ethers and hence cause liver lesions. The aim of this study was to investigate the effects of isoflurane on the activity of ALT-AST-ALP-GGT enzymes...

متن کامل

Assessment of an ore body internal dilution based on multivariate geostatistical simulation using exploratory drill hole data

Dilution can best be defined as the proportion of waste tonnage to the total weight of ore and waste in each block. Predicting the internal dilution based on geological boundaries of waste and ore in each block can help engineers to develop more reliable long-term planning designs in mining activities. This paper presents a method to calculate the geological internal dilution in each block and ...

متن کامل

Development of a Sensitive Spectrofluorometric-Multivariate Calibration Method for Enzyme Kinetic of Aldehyde Oxidase

Attempts to obtain experimental values for the kinetic parameters of phenanthridine oxidation by guinea pig or rabbit liver aldehyde oxidase using common spectrophotometric methods have not been successful due to a lower limit of detection. In the present study, a new spectrofluorimetric assay in combination with a multivariate calibration method for enzymatic kinetic study of aldehyde oxidase ...

متن کامل

Development of a Sensitive Spectrofluorometric-Multivariate Calibration Method for Enzyme Kinetic of Aldehyde Oxidase

Attempts to obtain experimental values for the kinetic parameters of phenanthridine oxidation by guinea pig or rabbit liver aldehyde oxidase using common spectrophotometric methods have not been successful due to a lower limit of detection. In the present study, a new spectrofluorimetric assay in combination with a multivariate calibration method for enzymatic kinetic study of aldehyde oxidase ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Drug metabolism and disposition: the biological fate of chemicals

دوره 27 6  شماره 

صفحات  -

تاریخ انتشار 1999