Tracer gas experiments in subways using an integrated measuring and analysis system for sulfur hexafluoride

نویسندگان

  • M. Brüne
  • J. Spiegel
  • K. Potje-Kamloth
  • C. Stein
  • A. Pflitsch
چکیده

Abstract. Several sulfur hexafluoride (SF6) tracer gas experiments were conducted in a subway system to measure the possible pathways of toxic gas for subway tunnels and stations empirically. A new mobile integrated measuring and analysis system was used to achieve high sample rates and a long measurement time. Due to the mobility of the sensors, tracer gas experiments were also carried out inside running subway coaches. All experiments showed a common pattern: the pathways of tracer gas dispersion overlapped with some escape routes, which were contaminated within a few minutes. So in case of catastrophic circumstances like terrorist attacks or subway fires, some escape routes will become deathly traps, but the results also showed free escape routes. With the new sensor technique it will be possible to conduct safety assessments for escape routes in underground transportation facilities.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

VERY DEEP TRENCHES IN SILICON WAFER USING DRIE METHOD WITH ALUMINUM MASK

Abstract: In this paper, a DRIE process for fabricating MEMS silicon trenches with a depth of more than 250 m is described. The DRIE was produced in oxygen-added sulfur hexafluoride (SF6) plasma, with sample cooling to cryogenic temperature using a Plasmalab System 100 ICP 180 at different RF powers. A series of experiments were performed to determine the etch rate and selectivity of the some m...

متن کامل

Intermediate-Scale Tests of the Gas-Phase Partitioning Tracer Method for Measuring Soil-Water Content

Turfgrass Research. The lysimeter is 4.0 m deep, 2.5 m in diameter, and contains a homogeneous packing of Vinton fine Experiments were conducted in a well-instrumented weighing lysand (sandy, mixed, thermic Typic Torrifluvents) with a mean simeter (2.5 by 4 m) to evaluate the efficacy of the gas-phase-partibulk density of 1.38 Mg m 3 and porosity of 0.47. Details tioning tracer method for measu...

متن کامل

The carbon dioxide leakage from chambers measured using sulfur hexafluoride

In plant chamber studies, if CO2 leaking from a chamber is not quantified, it can lead to an overestimate of assimilation rates and an underestimate of respiration rates; consequently, it is critical that CO2 leakage be determined. Sulfur hexafluoride (SF6) was introduced into the chambers as a tracer gas to estimate leakage rates. Chamber leakage constants were determined by measuring the rate...

متن کامل

High-sensitivity photoacoustic leak testing.

The photoacoustic effect may be exploited for the detection and localization of gas leaks from otherwise sealed components. The technique involves filling the test component with a tracer gas, and radiating the component to produce photoacoustic sound from any leak site where tracer gas is present. This paper describes demonstration experiments utilizing 10.6-micro radiation from a carbon-dioxi...

متن کامل

A rapid method for the measurement of sulfur hexafluoride (SF6), trifluoromethyl sulfur pentafluoride (SF5CF3), and Halon 1211 (CF2ClBr) in hydrologic tracer studies

[1] A rapid headspace method for the simultaneous laboratory determination of intentionally introduced hydrologic tracers, sulfur hexafluoride (SF6), trifluoromethyl sulfur pentafluoride (SF5CF3), Halon 1211 (CF2ClBr), and other halocarbons in water and gases is described. The high sensitivity of the procedure allows for introduction of minimal tracer mass (a few grams) into hydrologic systems ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016