Safe to Handle? Comparing Manually and Machine-Washed Medical Devices.

نویسندگان

  • Kaumudi Kulkarni
  • Dzelma Kaczorowski
  • Alex Bonkowski
  • Stephen Kovach
  • Ralph Basile
چکیده

The goal of medical device reprocessing is to ensure that a given device is ready for safe use on the next patient. Effective cleaning of devices is critical to achieving this goal. Device cleaning also has had an ancillary goal: rendering the device safe for handling with ungloved hands by sterile processing personnel. Such personnel are tasked with preparing the device for further reprocessing steps, such as packaging for sterilization. This raises the question: Are manually cleaned devices as safe to handle as machinewashed medical devices? The current study sought to gather data to help answer this question. Further, this study sought to evaluate the effectiveness of a relatively new tool in the area of decontamination in healthcare settings—ultraviolet (UV) disinfection—and whether UV disinfection could effectively and efficiently be used to render manually cleaned devices safer to handle. Mechanically washed reusable medical devices generally are considered to have a more reliable and effective level of cleanliness, as supported by the limited research available in this area.1 The underlying logic for this assertion is that mechanical methods are more robust and reliably repeatable compared with manual methods.2 Machine washing allows for the use of cleaning solutions at much higher temperatures. These higher temperatures typically include a detergent wash at 60°C (150°F), followed by thermal disinfection at 82°C to 93°C (180°F to 195°F) for one minute or longer.3 Further, the cycle settings are programmed into a machine and are repeated cycle after cycle. Conversely, manual cleaning depends on the individual performance of the person conducting the cleaning. These assertions do not devalue the importance of reprocessing staff. To the contrary, even the most simply designed medical device requires proper and effective precleaning by manual means. Typically speaking, the more complex the device, the more important the manual steps to prepare the device for further cleaning by mechanical means. Further, a substantial number of medical devices cannot undergo mechanical cleaning. This is due to the material used in construction (i.e., thermolabile, nonsubmersible) and/or the complexity of the design.4 Effective cleaning of these devices is wholly reliant on manual processes. By design, sterile processing departments typically have a physical separation between the area where items are cleaned (the “dirty side”) and the area to which they are transported for further processing, such as sterilization (the “clean side”). Mechanical cleaning equipment typically is designed with a dual door design, where the loading door is located on the dirty side and the unloading door on the clean side. For manually cleaned devices, and for passing items back from the clean to the dirty side for recleaning, sterile processing departments typically have a “pass-through” window. Safe to Handle? Comparing Manually and Machine-Washed Medical Devices

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ghost Image Mapping of Palatal Bone of Maxilla and Nasal Cavity in Panoramic View Using Cranex D Digital Machine

Introdouction: The mapping of ghost images of the maxilla and the nasal cavity, which are complex structures, is very important. The position of objects that create a ghost image can differ when using various devices. The purpose of this investigation was to study the mapping of ghost images of the maxilla and the nasal cavity using a Cranex D digital panoramic machine. Materials and methods: ...

متن کامل

The role of aortouniiliac devices in the treatment of aneurysmal disease.

PURPOSE Many studies have shown that aortouniiliac (AUI) devices have comparable outcome in high risk patients as the treatment with bifurcated devices. The purpose of this article is to review the relevant literature and discuss the outcomes. METHODS A systematic search from 1991 until 2010 was performed on PubMed and Medline databases for studies evaluating the role of AUI devices accompani...

متن کامل

Evaluation of the Quality Control Program for Diagnostic Radiography and Fluoroscopy Devices in Syria during 2005-2013

Introduction: Extensive use of diagnostic radiology is the largest contributor to total population radiation doses. Thus, appropriate equipment and safe practice are necessary for good-quality images with optimal doses. This study aimed to perform quality control (QC) audit for radiography and fluoroscopy devices owned by private sector in Syria (2005-2013) to verify compliance of performance o...

متن کامل

Verification of delivered dose to the Lips carcinoma tumors with HDR brachytherapy sources: 192Ir and 60CO in an exclusive plexiglass Phantom.

Introduction: Brachytherapy, especially using manually after loaded Iridium-192 and Cobalt-60, can be applied as a sole treatment, as a treatment complementary to surgery, and as a local boost in combination with EBRT. The use of HDR brachytherapy catheters incorporated in removable dental molds allows repeated, highly reproducible, fractionated outpatient brachytherapy of supe...

متن کامل

Determining and Rating Environmental Aspects caused by the Production Process of Oxygenating Machine, Infectious Wastes Disinfection Device, and an Autoclave System with an Emphasis on Fuzzy AHP

Introduction: The medical device industry plays a special role in promoting the health and safety of the community. Its proper and optimal management can also significantly affect the national development of any country in terms of economics, health, medical education, and research. The present study attempted to evaluate the impact of environmental aspects of the medical device manufacturing u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biomedical instrumentation & technology

دوره Suppl  شماره 

صفحات  -

تاریخ انتشار 2016