The recent growing diffusion of dispersed generation in low voltage (LV) distribution networks is entailing new rules to make local generators participate in network stability. Consequently, national and international grid codes, which define the connection rules for stability and safety of electrical power systems, have been updated requiring distributed generators and electrical storage systems to supply stabilizing contributions. In this scenario, specific attention to the uncontrolled islanding issue has to be addressed since currently required anti-islanding protection systems, based on relays locally measuring voltage and frequency, could no longer be suitable. In this paper, the effects on the interface protection performance of different LV generators’ stabilizing functions are analysed. The study takes into account existing requirements, such as the generators’ active power regulation (according to the measured frequency) and reactive power regulation (depending on the local measured voltage). In addition, the paper focuses on other stabilizing features under discussion, derived from the medium voltage (MV) distribution network grid codes or proposed in the literature, such as fast voltage support (FVS) and inertia emulation. Stabilizing functions have been reproduced in the DIgSILENT PowerFactory 2016 software environment, making use of its native programming language. Later, they are tested both alone and together, aiming to obtain a comprehensive analysis on their impact on the anti-islanding protection effectiveness. Through dynamic simulations in several network scenarios the paper demonstrates the detrimental impact that such stabilizing regulations may have on loss-of-main protection effectiveness, leading to an increased risk of unintentional islanding.
منابع مشابه
Islanding Detection Method of Distributed Generation Based on Wavenet
Due to the increasing need to distributed energy resources in power systems, their problems should be studied. One of the main problem of distributed energy resources is unplanned islanding. The unplanned islanding has some dangers to the power systems and the repairman which are works with the incorrect devices. In this paper, a passive local method is proposed. The proposed method is based on...
متن کاملRadial Basis Neural Network Based Islanding Detection in Distributed Generation
This article presents a Radial Basis Neural Network (RBNN) based islanding detection technique. Islanding detection and prevention is a mandatory requirement for grid-connected distributed generation (DG) systems. Several methods based on passive and active detection scheme have been proposed. While passive schemes have a large non detection zone (NDZ), concern has been raised on active method ...
متن کاملAn Intelligent Anti-Islanding Scheme for Synchronous-Based Distributed Generation Using Reduced-Noise Morphological Gradient
This paper presents a pattern recognition-based scheme for detection of islanding conditions in synchronous- based distributed generation (DG) systems. The main idea behind the proposed scheme is the use of spatial features of system parameters such as the frequency, magnitude of positive sequence voltage, etc. In this study, the system parameters sampled at the point of common coupling (PCC) w...
متن کاملDistributed Energy Resources Protection Requirements in Future Distribution Grids
One of the key protection functionalities in the future active distribution networks will be reliable detection of islanding. Non-detection zone (NDZ) near a power balance situation and maloperation due to other network events have been the major challenges with traditional passive islanding detection methods like voltage, frequency, rate-ofchange-of-frequency, voltage vector shift (VVS). Howev...
متن کاملIslanding Detection and Frequency Circuit Measurement by Power Distribution Relation Depending on the Angle
This paper presents a new islanding detection method based on the difference of the power transfer angle between the distributed generation and local load. After islanding, current id and iq will be changed by adding the variation to d_q transformation block of current. This makes voltage and frequency disturbance and therefore islanding is recognized. Active islanding detection method usually ...