Wideband Bio-impedance Spectroscopy using Voltage Source and Tetra-polar Electrode Configuration
نویسندگان
چکیده
Most bio-impedance spectroscopy (BIS) systems inject sinusoidal current with a variable frequency into a sample with a known geometry through a pair of electrodes. Adopting the so-called tetra-polar configuration, it measures induced voltage data on a separate pair of electrodes. Impedance spectra are plotted in a certain range of frequency. We found that its accuracy decreases at high frequencies primarily due to the deteriorated performance of the constant current source at high frequencies. Using a previous BIS system we developed, we found that the overall performance can be kept high up to several hundred kHz. In this study, we propose a design of a wideband BIS system using a constant voltage source. It is based on the simple voltage division between an internal resistor and an external sample or load. We switch the value of the internal resistor (Rs) so that the source voltage is divided more or less equally. Two pairs of electrodes are attached to the sample. Two independent voltmeters are used to separately measure two voltages across the chosen internal resistor and the sample. The voltage measurement across the sample is done between the second electrode pair only. This enables us to adopt the tetra-polar configuration to avoid the problem related with contact impedances. We describe the design, construction and performance of the new BIS system with 468 Hz to 2.2 MHz bandwidth. We will compare the results with those using the impedance analyzer. Keyword: bio-impedance spectroscopy, voltage source
منابع مشابه
Non - invasive Bio - impedance Measurement Using Voltage - Current Pulse Technique
Noninvasive detection is a fundamental prerequisite for pervasive healthcare system and biosensing. Along with different noninvasive techniques such as ultrasound, X-ray, magnetic resonance and optical imaging, electrical impedance spectroscopy is emerging as more suitable technique for tissue level diagnosis. This paper presents a noninvasive technique for bioelectrical impedance estimation by...
متن کاملRelative Measurement of Differential Electrode Impedance for Contact Monitoring in a Biopotential Amplifier 601 Relative Measurement of Differential Electrode Impedance for Contact Monitoring in a Biopotential Amplifier
In this paper, we propose a simple and relative electrode contact monitoring method. By exploiting the power line interference, which is regarded as one of the worst noise sources for bio-potential measurement, the relative difference in electrode impedance can be measured without a current or voltage source. Substantial benefits, including no extra circuit components, no degradation of the bod...
متن کاملSimple voltage-controlled current source for wideband electrical bioimpedance spectroscopy: circuit dependences and limitations
In this work, the single Op-Amp with load-in-the-loop topology as a current source is revisited. This circuit topology was already used as a voltage-controlled current source (VCCS) in the 1960s but was left unused when the requirements for higher frequency arose among the applications of electrical bioimpedance (EBI). The aim of the authors is not only limited to show that with the currently a...
متن کاملFabrication and Electrochemical Behavior of Monoclinic CuO and CuO/Graphite Composite Nanoparticles as Cathode in an Alkaline Zn-CuO Battery
Electrochemical properties of various rock-shaped-CuO/graphite (G) composites and monoclinic structure CuO nanoparticles as the cathode versus a zinc plate as the anode in a 4M NaOH electrolyte were elucidated by electrochemical impedance spectroscopy (EIS) and chronopotentiometry (CP) in a two electrode configuration cell. Various values of G 9, 16 and 28 wt% were prepared and studied as catho...
متن کاملFlexible Electrode Array for Retinal Stimulation
In this Work, ITO/PET (Indium Tin Oxide / Polyethylene Terephthalate) electrode structure which provides biocompatibility, mechanical stability and flexibility is fabricated. Flexible ITO/PET implantable electrode array for a retina has been developed. The electrode array is fabricated on a thin PET/ITO substrate and is encapsulated using, SU-8, an insulating material. PET substrate and SU-8 po...
متن کامل