Determination of serum calcium by use of an AutoAnalyzer I-II hybrid.

نویسندگان

  • C L Jacklyn
  • C D Freeman
  • M E Gray
  • M A MacAulay
چکیده

A hybridized system is described for the continuousflow determination of serum calcium. The analysis is based on the cresolphthalein colorimetric procedure as described for use with the SMA 12/60 (Technicon Corp.). The hydraulic features of the AutoAnalyzer II are used with modules of the AutoAnalyzer 1. This combination gives both the ease of operation and hydraulic improvements inherent in the AutoAnalyzer II system and provides an emergency alternative to the SMA 12/60, with which results are shown to be comparable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of serum or plasma glucose on the "AutoAnalyzer II" by use of the hexokinase reaction.

Manual procedures based on these reactions and involving the direct addition of serum to a single reagent are commonly used as emergency procedures in routine clinical chemistry laboratories of hospitals. We have adapted one of these methods, “Glucose 500-Pack” (Calbiochem, P.O. Box 12087, San Diego, Calif. 92772) to an automated method on the “AutoAnalyzer II” (Technicon Instruments Corp., Tar...

متن کامل

سطح سرمی و دفع ادراری کلسیم در نوزادان مبتلا به زردی غیرفیزیولوژیکِ تحت فتوتراپی

    Background and Aim: Hypocalcaemia has been reported as a complication of phototherapy especially in premature neonates. However, the cause is unknown. The aim of this study was to evaluate the relation between serum and urinary levels of calcium in neonates under phototherapy and to answer the question that whether phototherapy-related hypocalcemia is associated with hypercalicuria or not.P...

متن کامل

Automated fluorometric method for the determination of serum calcium.

A. FULLY automated nlethod for the (leterinination of serum calcium which is accurate, reproducible, and relatively simple seemed desirable. The additioll of the fluorometer (1) to the modular system of the AutoAnalyzer* suggested the search for a fluorometric calcium procedure. Accordingly, several substances known to complex with calcium were obtained and their fluorescent emission spectra in...

متن کامل

Automated, simultaneous microdetermination of calcium and magnesium by atomic absorption.

A procedure is described for the simultaneous, automatic determination of serum calcium and magnesium with the AutoAnalyzer, and a dualchannel, double-beam atomic absorption spectrophotometer, the IL Model 153. Advantages over existing procedures include a high rate of analysis (90 samples or 180tests per hour) and low sample consumption (a total of 30 l for both determinations). We have compar...

متن کامل

BIOCHEMICAL FINDINGS IN RICKETS AMONG ADOLESCENT GIRLS

 ABSTRACT Background: To determine daily calcium, Vitamin D intake and serum biochemical findings of rickets in adolescent girls. Methods: A total of 414 healthy adolescent student girls aged 11-15 years were evaluated from various areas of Tehran, Iran with different socioeconomic status. A randomized, cross-sectional, prospective and descriptive study was undertaken for calculation of daily c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 19 5  شماره 

صفحات  -

تاریخ انتشار 1973