Brominated and phosphate flame retardants (FRs) in indoor dust from different microenvironments: Implications for human exposure via dust ingestion and dermal contact.

نویسندگان

  • Xiaobo Zheng
  • Lin Qiao
  • Adrian Covaci
  • Runxia Sun
  • Huiying Guo
  • Jing Zheng
  • Xiaojun Luo
  • Qilai Xie
  • Bixian Mai
چکیده

Indoor dust has been widely used to monitor flame retardants (FRs) in indoor environment, but most studies only focused on floor dust. In the present study, FRs were examined in indoor dust from different locations. Dust from air conditioner (AC) filters, beddings, floor, and windows in bedrooms, and dust from AC filters, printer table surface, computer table surface, floor, and windows in offices were collected, respectively. Polybrominated diphenyl ether congener 209 (BDE 209) and decabromodiphenyl ethane (DBDPE) were the most abundant brominated flame retardants (BFRs), and tris(chloroisopropyl) phosphate (TCIPP), tris(1,3-dichloroisopropyl) phosphate (TDCIPP), and triphenyl phosphate (TPHP) were the most abundant phosphate flame retardants (PFRs). In bedrooms, the AC filter dust had the highest median levels of BDE 209 (536 ng/g) and DBDPE (2720 ng/g), while bed dust had the highest median levels of ΣPFRs (2750 ng/g) among dust samples. In offices, printer table dust had higher median levels of BDE 209 (1330 ng/g), DBDPE (8470 ng/g), and ΣPFRs (11,000 ng/g) than those in other dust samples. The high dust ingestion values of BDE 209, DBDPE, and individual PFR were 0.28, 1.20, and <0.01-0.32 ng/kg bw/day and 7.37, 31.2, and <0.01-4.54 ng/kg bw/day for BDE 209, DBDPE, and individual PFR for adults and toddlers, respectively. The high dermal exposure values of individual PFR during sleeping were <0.01-0.23 and <0.01-0.36 ng/kg bw/day for adults and toddlers, respectively. More human exposure pathways other than dust ingestion should be considered, such as the dermal contact with beddings and furniture.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Legacy and alternative flame retardants in Norwegian and UK indoor environment: Implications of human exposure via dust ingestion.

Indoor dust has been acknowledged as a major source of flame retardants (FRs) and dust ingestion is considered a major route of exposure for humans. In the present study, we investigated the presence of PBDEs and alternative FRs such as emerging halogenated FRs (EHFRs) and organophosphate flame retardants (PFRs) in indoor dust samples from British and Norwegian houses as well as British stores ...

متن کامل

Evaluating the Bioaccessibility of Flame Retardants in House Dust Using an In Vitro Tenax Bead-Assisted Sorptive Physiologically Based Method

Exposure to house dust is a significant source of exposure to flame retardant chemicals (FRs), particularly in the US. Given the high exposure there is a need to understand the bioaccessibility of FRs from dust. In this study, Tenax beads (TA) encapsulated within a stainless steel insert were used as an adsorption sink to estimate the dynamic absorption of a suite of FRs commonly detected in in...

متن کامل

Occurrence of alternative flame retardants in indoor dust from New Zealand: indoor sources and human exposure assessment.

Due to worldwide restrictions on polybrominated diphenyl ethers (PBDEs), the demand for alternative flame retardants (AFRs), such as organophosphate flame retardants (OPFRs), novel brominated FRs (NBFRs) and hexabromocyclododecanes (HBCDs), has recently increased. Little is known about human exposure to NBFRs and OPFRs and that their levels in dust have been scarcely evaluated worldwide. To inc...

متن کامل

Concentrations of organophosphate esters and brominated flame retardants in German indoor dust samples.

While it is known that the ingestion of indoor dust contributes substantially to human exposure to the recently restricted polybrominated diphenyl ethers (PBDEs), the situation for one class of potential replacements, i.e. organophosphate esters (OPEs), used in a variety of applications including as flame retardants has yet to be fully characterised. In this study, surface dust from twelve diff...

متن کامل

Monitoring Indoor Exposure to Organophosphate Flame Retardants: Hand Wipes and House Dust

BACKGROUND Organophosphate flame retardants (PFRs) are becoming popular replacements for the phased-out polybrominated diphenyl ether (PBDE) mixtures, and they are now commonly detected in indoor environments. However, little is known about human exposure to PFRs because they cannot be easily measured in blood or serum. OBJECTIVES To investigate relationships between the home environment and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chemosphere

دوره 184  شماره 

صفحات  -

تاریخ انتشار 2017