A Novel 12-Lead ECG T-Shirt with Active Electrodes
نویسندگان
چکیده
We developed an ECG T-shirt with a portable recorder for unobtrusive and long-term multichannel ECG monitoring with active electrodes. A major drawback of conventional 12-lead ECGs is the use of adhesive gel electrodes, which are uncomfortable during long-term application and may even cause skin irritations and allergic reactions. Therefore, we integrated comfortable patches of conductive textile into the ECG T-shirt in order to replace the adhesive gel electrodes. In order to prevent signal deterioration, as reported for other textile ECG systems, we attached active circuits on the outside of the T-shirt to further improve the signal quality of the dry electrodes. Finally, we validated the ECG T-shirt against a commercial Holter ECG with healthy volunteers during phases of lying down, sitting, and walking. The 12-lead ECG was successfully recorded with a resulting mean relative error of the RR intervals of 0.96% and mean coverage of 96.6%. Furthermore, the ECG waves of the 12 leads were analyzed separately and showed high accordance. The P-wave had a correlation of 0.703 for walking subjects, while the T-wave demonstrated lower correlations for all three scenarios (lying: 0.817, sitting: 0.710, walking: 0.403). The other correlations for the P, Q, R, and S-waves were all higher than 0.9. This work demonstrates that our ECG T-shirt is suitable for 12-lead ECG recordings while providing a higher level of comfort compared with a commercial Holter ECG.
منابع مشابه
Wearable Textile Electrodes for ECG Measurement
The electrocardiogram (ECG) is one of the most important parameters for monitoring of the physiological state of a person. Currently available systems for ECG monitoring are both stationary and wearable, but the comfort of the monitored person is not at a satisfactory level because these systems are not part of standard clothing. This article is therefore devoted to the development and measurem...
متن کاملDeriving the 12-lead Ecg from Easi Electrodes via Nonlinear Regression
The standard 12-lead Electrocardiogram (ECG) is the basic clinical method of heart disease diagnosis. Measuring all 12 leads is often cumbersome and impractical especially on a long term monitoring. In 1988, Gordon Dower has introduced an EASI-lead ECG System, where only 5 electrodes are used. In order to gain all 12-lead ECG back from this EASI system, Dower’s equation was proposed then. Ever ...
متن کاملDevelopment of Hydrogel Membranes for Long Term Biopotential Monitoring Using Flexible Wet Electrodes
Ubiquitous monitoring of biopotentials can greatly enhance comfort, health and safety of patients dealing with chronic diseases. For home use, clinical grade adhesive electrodes are often cited as irritating and uncomfortable, leading to low usage compliance [1]. For long-term monitoring it is mandatory to have innocuous and disposable electrodes with constant impedance over long periods of tim...
متن کاملModified electrode placement must be recorded when performing 12-lead electrocardiograms.
BACKGROUND Local observation has suggested that placing limb leads on the torso when recording the standard 12-lead resting electrocardiogram (ECG) has become commonplace. This non-standard modification has the important advantages of ease and speed of application, and in an emergency may be applied with minimal undressing. Limb movement artefact is also reduced. It is believed that ECGs obtain...
متن کاملThe effects of electrode misplacement on clinicians' interpretation of the standard 12-lead electrocardiogram.
INTRODUCTION This study investigates how a particular incorrect electrode configuration affects the 12-lead Electrocardiogram (ECG). METHODS A correct and an incorrect 12-lead ECG were extracted from a 192-lead BSPM. This was done for 232 BSPMs yielding 464 12-lead ECGs. The particular incorrect ECG involved displacing electrodes V1 and V2 in the second intercostal space whilst also offsettin...
متن کامل