Three-dimensional prostate segmentation using level set with shape constraint based on rotational slices for 3D end-firing TRUS guided biopsy.
نویسندگان
چکیده
PURPOSE Prostate segmentation is an important step in the planning and treatment of 3D end-firing transrectal ultrasound (TRUS) guided prostate biopsy. In order to improve the accuracy and efficiency of prostate segmentation in 3D TRUS images, an improved level set method is incorporated into a rotational-slice-based 3D prostate segmentation to decrease the accumulated segmentation errors produced by the slice-by-slice segmentation method. METHODS A 3D image is first resliced into 2D slices in a rotational manner in both the clockwise and counterclockwise directions. All slices intersect approximately along the rotational scanning axis and have an equal angular spacing. Six to eight boundary points are selected to initialize a level set function to extract the prostate contour within the first slice. The segmented contour is then propagated to the adjacent slice and is used as the initial contour for segmentation. This process is repeated until all slices are segmented. A modified distance regularization level set method is used to segment the prostate in all resliced 2D slices. In addition, shape-constraint and local-region-based energies are imposed to discourage the evolved level set function to leak in regions with weak edges or without edges. An anchor point based energy is used to promote the level set function to pass through the initial selected boundary points. The algorithm's performance was evaluated using distance- and volume-based metrics (sensitivity (Se), Dice similarity coefficient (DSC), mean absolute surface distance (MAD), maximum absolute surface distance (MAXD), and volume difference) by comparison with expert delineations. RESULTS The validation results using thirty 3D patient images showed that the authors' method can obtain a DSC of 93.1% ± 1.6%, a sensitivity of 93.0% ± 2.0%, a MAD of 1.18 ± 0.36 mm, a MAXD of 3.44 ± 0.8 mm, and a volume difference of 2.6 ± 1.9 cm(3) for the entire prostate. A reproducibility experiment demonstrated that the proposed method yielded low intraobserver and interobserver variability in terms of DSC. The mean segmentation time of the authors' method for all patient 3D TRUS images was 55 ± 3.5 s, in addition to 30 ± 5 s for initialization. CONCLUSIONS To address the challenges involved with slice-based 3D prostate segmentation, a level set based method is proposed in this paper. This method is especially developed for a 3D end-firing TRUS guided prostate biopsy system. The extensive experimental results demonstrate that the proposed method is accurate, robust, and computationally efficient.
منابع مشابه
Rotationally resliced 3D prostate TRUS segmentation using convex optimization with shape priors.
PURPOSE Efficient and accurate segmentations of 3D end-firing transrectal ultrasound (TRUS) images play an important role in planning of 3D TRUS guided prostate biopsy. However, poor image quality of the input 3D TRUS images, such as strong imaging artifacts and speckles, often makes it a challenging task to extract the prostate boundaries accurately and efficiently. METHODS In this paper, th...
متن کاملA shape-based statistical method to retrieve 2D TRUS-MR slice correspondence for prostate biopsy
This paper presents a method based on shape-context and statistical measures to match interventional 2D Trans Rectal Ultrasound (TRUS) slice during prostate biopsy to a 2D Magnetic Resonance (MR) slice of a pre-acquired prostate volume. Accurate biopsy tissue sampling requires translation of the MR slice information on the TRUS guided biopsy slice. However, this translation or fusion requires t...
متن کاملA molecular image-directed, 3D ultrasound-guided biopsy system for the prostate
Systematic transrectal ultrasound (TRUS)-guided biopsy is the standard method for a definitive diagnosis of prostate cancer. However, this biopsy approach uses two-dimensional (2D) ultrasound images to guide biopsy and can miss up to 30% of prostate cancers. We are developing a molecular image-directed, three-dimensional (3D) ultrasound image-guided biopsy system for improved detection of prost...
متن کاملNeedle segmentation using 3D Hough transform in 3D TRUS guided prostate transperineal therapy.
PURPOSE Prostate adenocarcinoma is the most common noncutaneous malignancy in American men with over 200,000 new cases diagnosed each year. Prostate interventional therapy, such as cryotherapy and brachytherapy, is an effective treatment for prostate cancer. Its success relies on the correct needle implant position. This paper proposes a robust and efficient needle segmentation method, which ac...
متن کاملSegmenting TRUS Video Sequences Using Local Shape Statistics
Automatic segmentation of the prostate in transrectal ultrasound (TRUS) may improve the fusion of TRUS with magnetic resonance imaging (MRI) for TRUS/MRI-guided prostate biopsy and local therapy. It is very challenging to segment the prostate in TRUS images, especially for the base and apex of the prostate due to the large shape variation and low signal-to-noise ratio. To successfully segment t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 40 7 شماره
صفحات -
تاریخ انتشار 2013