Quantitative method to determine sporicidal decontamination of building surfaces by gaseous fumigants, and issues related to laboratory-scale studies.
نویسندگان
چکیده
Chlorine dioxide gas and vaporous hydrogen peroxide sterilant have been used in the cleanup of building interiors contaminated with spores of Bacillus anthracis. A systematic study, in collaboration with the U.S. Environmental Protection Agency, was jointly undertaken by the U.S. Army-Edgewood Chemical Biological Center to determine the sporicidal efficacies of these two fumigants on six building structural materials: carpet, ceiling tile, unpainted cinder block, painted I-beam steel, painted wallboard, and unpainted pinewood. Critical issues related to high-throughput sample processing and spore recovery from porous and nonporous surfaces included (i) the extraction of spores from complex building materials, (ii) the effects of titer challenge levels on fumigant efficacy, and (iii) the impact of bioburden inclusion on spore recovery from surfaces and spore inactivation. Small pieces (1.3 by 1.3 cm of carpet, ceiling tile, wallboard, I-beam steel, and pinewood and 2.5 by 1.3 cm for cinder block) of the materials were inoculated with an aliquot of 50 microl containing the target number (1 x 10(6), 1 x 10(7), or 1 x 10(8)) of avirulent spores of B. anthracis NNR1Delta1. The aliquot was dried overnight in a biosafety cabinet, and the spores were extracted by a combination of a 10-min sonication and a 2-min vortexing using 0.5% buffered peptone water as the recovery medium. No statistically significant drop in the kill efficacies of the fumigants was observed when the spore challenge level was increased from 6 log units to 8 log units, even though a general trend toward inhibition of fumigant efficacy was evident. The organic burden (0 to 5%) in the spore inoculum resulted in a statistically significant drop in spore recovery (at the 2 or 5% level). The effect on spore killing was a function of the organic bioburden amount and the material type. In summary, a high-throughput quantitative method was developed for determining the efficacies of fumigants, and the spore recoveries from five porous materials and one nonporous material ranged between 20 and 80%.
منابع مشابه
Decontamination Efficacy of Three Commercial-Off-The-Shelf (COTS) Sporicidal Disinfectants on Medium-Sized Panels Contaminated with Surrogate Spores of Bacillus anthracis
In the event of a wide area release and contamination of a biological agent in an outdoor environment and to building exteriors, decontamination is likely to consume the Nation's remediation capacity, requiring years to cleanup, and leading to incalculable economic losses. This is in part due to scant body of efficacy data on surface areas larger than those studied in a typical laboratory (5×10...
متن کاملFumigation of a laboratory-scale HVAC system with hydrogen peroxide for decontamination following a biological contamination incident.
AIMS To evaluate hydrogen peroxide vapour (H2 O2 ) for its ability to inactivate Bacillus spores within a laboratory-scale heating, ventilation and air-conditioning (HVAC) duct system. METHODS AND RESULTS Experiments were conducted in a closed-loop duct system, constructed of either internally lined or unlined galvanized metal. Bacterial spores were aerosol-deposited onto 18-mm-diameter test ...
متن کاملComparison of Sporicidal Activities of Commercial Disinfectant Wipes for Surface Decontamination
Li Chen: Comparison of Sporicidal Activities of Commercial Disinfectant Wipes for Surface Decontamination (Under the direction of Sally Mauriello) Digital intraoral receptors present an infection control challenge since they cannot be sterilized using traditional methods. This study evaluated the sporicidal effectiveness of CaviWipe ® , Volo ™ , and Dispatch ® wipes by directly treating spore s...
متن کاملMethod for disinfecting large enclosures with beta-propiolactone vapor.
This paper presenits a practical method for disinfecting large enclosures with 0-propiolactone (BPL) vapor, as well as precautions to be taken when using the chemical. Included are the summaries of tests in which a U. S. Army barrack, a hospital ward dayroom, an entire hospital wing, and a wing of an animal housing building were treated by the described procedure. The application of liquid disi...
متن کاملA Model of Architectural Factors Influence on Students' Perception of School Climate for Providing School Connectedness
Background and Objectives: The aim of this research was to introduce architectural factors, influencing students' perception of school climate, having a great effect on students' achievement academically, mentally and physically, one of the problems of high school students is their unwillingness for learning and passes their times at educational setting. School connectedness has an effect on st...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied and environmental microbiology
دوره 75 11 شماره
صفحات -
تاریخ انتشار 2009