Comparison of chromatographic methods for quality control of DMSA complexes with 99mTc and 188Re at (III) and (V) oxidation states.

نویسندگان

  • Piotr Garnuszek
  • Dariusz Pawlak
  • Michał Maurin
  • Drina Jankovic
  • Urszula Karczmarczyk
  • Renata Mikołajczak
چکیده

BACKGROUND The reliable method for determination of identity and radiochemical purity (RCP) is of great importance in radiopharmaceutical development. This is especially relevant when more than one form of radiometal/ligand complex can be formed during radiolabelling, such as complexes of 99mTc or 188Re with meso-2,3-dimercaptosuccinic acid (DMSA), where depending on the pH, metal can occur either at +3 or +5 oxidation state. The aim of our study was to evaluate possibilities for optimization of chromatographic systems leading to specific and reliable analytical method for determination of the identity and RCP of DMSA complexes with 99mTc or 188Re. MATERIAL AND METHODS The commercial DMSA kits (POLATOM) were used for preparation of technetium-99m (III) and (V) complexes with DMSA. 99mTc(V)-DMSA complexes were prepared by addition of NaHCO3 to the kit vial prior to 99mTc-eluate to obtain pH ~8. 188Re(V)-DMSA was prepared either directly or using intermediate 188Re(III)-EDTA complex added to DMSA. RCP was evaluated by TLC using: ITLC-SG developed in methylethylketon, SG60 coated plates developed in: n-BuOH/H2O/CH3COOH and n-PrOH/H2O/CH3COOH systems, and in H2O. Comparative biodistribution studies were performed in normal Wistar rats. RESULTS Using silica gel plates and n-PrOH, H2O and acetic acid in the developing solution, we observed that 99mTc/188Re(III)-DMSA and 99mTc/188Re(V)-DMSA complexes could be well separated from each other and from the impurities in the form of free pertechnetate/perrhenate. In vivo studies showed quite different biodistribution of 99mTc(III)- and 99mTc(V)-DMSA. The trivalent complex accumulated mainly in kidneys (>40%ID), while 99mTc(V)-DMSA revealed high excretion with urine and relatively high concentration in osseous tissue (ca. 2 %ID/g). Accumulation of this complex in kidneys was very low (ca. 2.5 %ID). Biodistribution pattern of 188Re(V)-DMSA prepared directly was almost identical to that of 99mTc(V)-DMSA. Biodistribution results of the 188Re preparation obtained using 188Re(III)-EDTA intermediate indicated that the preparation contained the mixture of penta- and trivalent 188Re complexes. The quite high accumulation of radioactivity in kidneys (23 %ID) gave evidence of the presence of 188Re(III)-DMSA in this preparation, what was also confirmed by the results of TLC analysis performed using silica gel plate and n-propanol/water/acetic acid as developing system. CONCLUSIONS Based on our study, we have made recommendation on the suitable methods for investigations of RCP of DMSA complexes, i.e.: SG60 plates developed in the mixture of n-propanol/water/acetic acid, which enable determination of the tri- and pentavalent DMSA complexes, as well as, the pertechnetate/perrhenate impurity, and developed in water for determination of the colloidal residue.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

99mTc-DMSA (V) in detection of metastases of medullary thyroid carcinoma

Introduction: Medullary thyroid carcinoma (MTC) is a rare thyroid cancer secreting calcitonin (CT) which is the most sensitive and specific tumor marker for MTC. This type of thyroid cancer is able to metastasize to different body areas including regional lymph nodes, lungs, liver and bone. The aim of this study was to assess the sensitivity and specificity of [99mTc-DMSA (V)] whole body ...

متن کامل

Comparison of IVP-simulator and 99mTc-DMSA renal scaning for renal localization and shielding in candidates for radiation therapy [Persian]

To minimize renal radiation in abdomical radiotherapy, shielding of the kidneys is essential. IVP-simulator is used as an standard method. In this study, we used 99mTc-DMSA to localize and shield the Kidneys and we compared this method with IVP-simulator. The size of the kidneys was proven to be larger as compared with IVP method. The mean of the overlap percentage was 81.88 in right and ...

متن کامل

The comparison between ultrasonography and 99mTc-DMSA renal scan in estimation of kidney size

Introduction: Renal length measurement is an important diagnostic clue in several urinary tract abnormalities. Although ultra sonography is the most frequent used modality for renal size estimation, renal diameter assessment by 99mTc-DMSA scintigraphy is of great value. By now, pointing to the renal size in the 99mTc-DMSA scintigraphy report has not been recommended by gui...

متن کامل

Diuretic effect on the measurement of differential renal function using 99mTc-DMSA in patients with hydronephrosis [Persian]

Introduction: It has been suggested that calculation of differential renal function (DRF) using 99mTc-DMSA may lead to overestimation of the function of an obstructed kidney. The aim of this study was to evaluate the effect of diuretic administration on the determination of DRF using 99mTc-DMSA scintigraphy in patients with dilated pelvis. Methods: Thirty three patients, aged from 2 month...

متن کامل

تخمین دوز جذبی ناشی از رادیوداروی 99mTc-DMSA در بیماران کودک تحت اسکن کلیه با استفاده از نرم‌افزار MIRDose و با بکارگیری روش ترکیبی پلنار SPECT

Introduction: 99mTc–Dimercaptosuccinic Acid (DMSA) as evaluation of pediatric genitourinary abnormalities has an important role in pediatric nuclear medicine. The aim of this study was to estimate organs absorbed dose for children injected by 99mTc DMSA using MIRDOSE software and hybrid planar/SPECT method. Methods: After injection of 99mTc-DMSA, ten children with genitourinary abnorma...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nuclear medicine review. Central & Eastern Europe

دوره 15 2  شماره 

صفحات  -

تاریخ انتشار 2012