RF-MEMS Load Sensors with Enhanced Q-factor and Sensitivity in a Suspended Architecture.

نویسندگان

  • Rohat Melik
  • Emre Unal
  • Nihan Kosku Perkgoz
  • Christian Puttlitz
  • Hilmi Volkan Demir
چکیده

In this paper, we present and demonstrate RF-MEMS load sensors designed and fabricated in a suspended architecture that increases their quality-factor (Q-factor), accompanied with an increased resonance frequency shift under load. The suspended architecture is obtained by removing silicon under the sensor. We compare two sensors that consist of 195 μm × 195 μm resonators, where all of the resonator features are of equal dimensions, but one's substrate is partially removed (suspended architecture) and the other's is not (planar architecture). The single suspended device has a resonance of 15.18 GHz with 102.06 Q-factor whereas the single planar device has the resonance at 15.01 GHz and an associated Q-factor of 93.81. For the single planar device, we measured a resonance frequency shift of 430 MHz with 3920 N of applied load, while we achieved a 780 MHz frequency shift in the single suspended device. In the planar triplet configuration (with three devices placed side by side on the same chip, with the two outmost ones serving as the receiver and the transmitter), we observed a 220 MHz frequency shift with 3920 N of applied load while we obtained a 340 MHz frequency shift in the suspended triplet device with 3920 N load applied. Thus, the single planar device exhibited a sensitivity level of 0.1097 MHz/N while the single suspended device led to an improved sensitivity of 0.1990 MHz/N. Similarly, with the planar triplet device having a sensitivity of 0.0561 MHz/N, the suspended triplet device yielded an enhanced sensitivity of 0.0867 MHz/N.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simulation of RF-MEMS Bio Implantable Sensor for Orthopedic Application

The ability to telemetrically measure strain is important in many aspects of daily life which brings important scientific and technological challenges in many sectors such as civil engineering, aircraft modeling, etc..,. Another unrealized, application area is human medicine and healthcare. MEMS (Micro ElectroMechanical System) technology for Radio Frequency applications has emerged in recent y...

متن کامل

Design of Novel High Sensitive MEMS Capacitive Fingerprint Sensor

In this paper a new design of MEMS capacitive fingerprint sensors is presented. The capacitive sensor is made of two parallel plates with air gap. In these sensors, the capacitance changes is very important factor. It is caused by deformation of the upper electrode of sensor. In this study with making slots in upper electrode, using T-shaped protrusion on diaphragm in order to concentrate the f...

متن کامل

A Novel MEMS Technological Platform Aimed at RF Applications

A novel MEMS technological platform for RF passive components, namely RF MEMS switches, tuneable capacitors and high-Q suspended inductors, is reported. The proposed process employs a metal (Al, AlSi or Cu) as active movable layer and amorphous silicon or polycrystalline silicon as sacrificial layers, providing multi-air-gaps. Various types of substrates like bulk silicon and SOI can be used. F...

متن کامل

Simulation and Derivation of Deflection Equation for Suspended Diaphragm for MEMS Application Using Kirchhoff-Love Theory

In this paper, using theory of sheets, the deflection of suspended diaphragm has been obtained under uniform and circular loading. This type of diaphragm, unlike other diaphragms, has a central support which is recommended to be used in MEMS applications. The relationship between diaphragm deflection and static analysis of this diaphragm enjoys a great significance in investigating and understa...

متن کامل

Accurate Model of Capacitance for MEMS Sensors using Corrugated Diaphragm with Residual Stress

In this paper we present a new model for calculating the capacitance of MEMS sensor with corrugated diaphragm. In this work the effect of residual stress is considered on deflection of diaphragm and capacitance of sensor. First, a new analytical analyzes have been carried out to derive mathematic expressions for central deflection of corrugated diaphragm and its relationship with residual stres...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Microelectronic engineering

دوره 88 3  شماره 

صفحات  -

تاریخ انتشار 2011