Venous cuff pressures from 30 mmHg to diastolic pressure are recommended to measure arterial inflow by plethysmography.

نویسندگان

  • Jan T Groothuis
  • Linda van Vliet
  • Miriam Kooijman
  • Maria T E Hopman
چکیده

Venous occlusion strain gauge plethysmography (VOP) is based on the assumption that the veins are occluded and arterial inflow is undisturbed by the venous cuff pressure. Literature is not clear concerning the pressure that should be used. The purpose of this study was to determine the optimal venous occlusion pressure at which the highest arterial inflow is achieved in the forearm, calf, and leg by using VOP. We hypothesized that, for each limb segment, an optimal (range of) venous cuff pressure can be determined. Arterial inflow in each limb segment was measured in nine healthy individuals by VOP by using pressures ranging from 10 mmHg up to diastolic blood pressure. Arterial inflows were similar at cuff pressures between 30 and 60 mmHg for the forearm, leg, and calf. Arterial inflow in the forearm was significantly lower at 10 mmHg compared with the other cuff pressures. In addition, arterial inflows at 20 mmHg tended to be lower in each limb segment than flow at higher cuff pressures. In conclusion, no single optimum venous cuff pressure, at which a highest arterial inflow is achieved, exists, but rather a range of optimum cuff pressures leading to a similar arterial inflow. Venous cuff pressures ranging from 30 mmHg up to diastolic blood pressure are recommended to measure arterial inflow by VOP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inhibition of prostaglandin synthesis does not alter the decrease in pre-capillary resistance in the human calf in response to small cumulative increases in venous congestion.

The decrease in pre-capillary resistance in the human calf during gradual cumulative increases in venous congestion pressure has been proposed to represent vasodilator signalling between the venous and arterial microcirculations. The present study investigated whether prostaglandins are involved in this local flow regulation by measuring calf blood flow and microvascular filtration capacity usi...

متن کامل

Measurements of vascular function using strain-gauge plethysmography: technical considerations, standardization, and physiological findings.

The main purpose of the present study was to examine the relationships between measures of fitness [estimated peak oxygen consumption (V(O2) peak) and handgrip strength] and forearm vascular function in 55 young (22.6 +/- 3.5 yr) adults. In addition, the present study considered methodological and technical aspects regarding the examination of the venous system using mercury in-Silastic strain-...

متن کامل

Peripheral arterial volume distensibility

A new arterial distensibility measurement technique was assessed in 100 healthy normotensive subjects. Arterial transmural pressures on the whole right arm were reduced with a 50 cm long cuff inflated to 10, 20, 30 and 40 mmHg. The electrocardiogram, and finger and ear photoplethysmograms were recorded simultaneously. Arm pulse propagation time, pulse wave velocity (PWV) and arterial volume dis...

متن کامل

Comparative haemodynamic and peripheral vasodilator effects of oral and chewable isosorbide dinitrate in patients with refractory congestive cardiac failure.

venous capacitance, and calf blood flow were compared in a double-blind trial in 18 patients with refractory chronic congestive heart failure with pulmonary artery end-diastolic pressures >18 mmHg. Cardiac output and right heart pressures were measured with a Swan-Ganz thermodilution catheter, arterial pressure through an indwelling radial artery cannula, and venous capacitance and calf blood f...

متن کامل

A novel noninvasive impedance-based technique for central venous pressure measurement.

Knowledge of central venous pressure (CVP) is considered valuable in the assessment and treatment of various states of critical illness and injury. We tested a noninvasive means of determining CVP (NICVP) by monitoring upper arm blood flow changes in response to externally applied circumferential pressure to the upper arm veins. Thirty-six patients who were undergoing CVP monitoring as part of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 95 1  شماره 

صفحات  -

تاریخ انتشار 2003