Assessment of Image Distortion from Head Rotation in Lateral Cephalometry
نویسندگان
چکیده
BACKGROUND The patient's head can be slightly rotated sagitally vertically or transversely within the head holding device. Because of such improper positions due to the head rotation, an error can occur in cephalometric measurements. The purpose of this study was to identify the potential projection errors of lateral cephalometric radiograph due to head rotation toward X-ray film in the vertical Z-axis. MATERIALS AND METHODS Totally, 10 human dry skulls with permanent dentition were collected from the Department of Anatomy, J.J.M.C. Medical College, Davanagere. Each dry skull was rotated from 0° to -20° at 5° intervals. A vertical axis, the Z-axis, was used as a rotational axis to have 100 lateral cephalometric radiographs exposed. Four linear (S-N, Go-Me, N-Me, S-Go) and six angular measurements (SNA, SNB, N-S-Ar, S-Ar-Go, Ar-Go-Me, AB-Mandibular plane angle) were calculated manually. RESULTS The findings were that: (1) Angular measurements have fewer projection errors than linear measurements; (2) the greater the number of landmarks on the midsagittal plane that are included in angular measurements, the fewer the projection errors occurring; (3) the horizontal linear measurements have more projection errors than vertical linear measurements according to head rotation. CONCLUSION In summary the angular measurements of lateral cephalometric radiographs are more useful than linear measurements in minimizing the projection errors associated with head rotation on a vertical axis.
منابع مشابه
Design, Construction and Evaluation of an Anthropomorphic Head Phantom for Assessment of Image Distortion in Stereotactic Radiosurgery Planning Systems
Introduction: In recent years, the use of magnetic resonance (MR) images in radiation treatment planning has drawn considerable attention. However, although the extent of a tumor can be determined in great detail on MR images, the geometric accuracy of these images is limited by distortions stemming from the inhomogeneity of the static background magnetic field, the nonlineari...
متن کاملEffect of Phase-Encoding Reduction on Geometric Distortion and BOLD Signal Changes in fMRI
Introduction Echo-planar imaging (EPI) is a group of fast data acquisition methods commonly used in fMRI studies. It acquires multiple image lines in k-space after a single excitation, which leads to a very short scan time. A well-known problem with EPI is that it is more sensitive to distortions due to the used encoding scheme. Source of distortion is inhomogeneity in the static B0 field that ...
متن کاملAssessment of Reproducibility of Geometric Distortion in MRI using Phantom Measurements
Introduction: Image distortion is one of the major problems of magnetic resonance imaging (MRI) for use in 3DMRI, velocity MRI, FMRI and radiotherapy treatment planning (RTTP). It is widely known that the most obvious effect of the inhomogenity of the magnetic fields and the nonlinearity of the gradient is the Geometric Distortion of MR tomograms. In this study, the...
متن کاملمقایسه دو تکنیک استاندارد و طبیعی (NHP) در رادیوگرافی سفالومتری لترال
Statement of Problem: Cephalometric findings are of high importance in making decision about orthodontic treatment plans and orthognathic surgeries. Natural head position (NHP) is considered as a useful and exact radiographic technique.Aim: The aim of the present study was to compare two techniques, namely Standard and NHP, in lateral cephalometry.Materials and Methods: In this cross- sectional...
متن کاملرفع اعوجاج هندسی متون بهکمک اطلاعات هندسی خطوط متن
Document images produced by scanners or digital cameras usually have photometric and geometric distortions. If either of these effects distorts document, recognition of words from such a document image using OCR is subject to errors. In this paper we propose a novel approach to significantly remove geometric distortion from document images. In this method first we extract document lines from do...
متن کامل