Impact of Reconstruction Algorithms on CT Radiomic Features of Pulmonary Tumors: Analysis of Intra- and Inter-Reader Variability and Inter-Reconstruction Algorithm Variability

نویسندگان

  • Hyungjin Kim
  • Chang Min Park
  • Myunghee Lee
  • Sang Joon Park
  • Yong Sub Song
  • Jong Hyuk Lee
  • Eui Jin Hwang
  • Jin Mo Goo
چکیده

PURPOSE To identify the impact of reconstruction algorithms on CT radiomic features of pulmonary tumors and to reveal and compare the intra- and inter-reader and inter-reconstruction algorithm variability of each feature. METHODS Forty-two patients (M:F = 19:23; mean age, 60.43±10.56 years) with 42 pulmonary tumors (22.56±8.51mm) underwent contrast-enhanced CT scans, which were reconstructed with filtered back projection and commercial iterative reconstruction algorithm (level 3 and 5). Two readers independently segmented the whole tumor volume. Fifteen radiomic features were extracted and compared among reconstruction algorithms. Intra- and inter-reader variability and inter-reconstruction algorithm variability were calculated using coefficients of variation (CVs) and then compared. RESULTS Among the 15 features, 5 first-order tumor intensity features and 4 gray level co-occurrence matrix (GLCM)-based features showed significant differences (p<0.05) among reconstruction algorithms. As for the variability, effective diameter, sphericity, entropy, and GLCM entropy were the most robust features (CV≤5%). Inter-reader variability was larger than intra-reader or inter-reconstruction algorithm variability in 9 features. However, for entropy, homogeneity, and 4 GLCM-based features, inter-reconstruction algorithm variability was significantly greater than inter-reader variability (p<0.013). CONCLUSIONS Most of the radiomic features were significantly affected by the reconstruction algorithms. Inter-reconstruction algorithm variability was greater than inter-reader variability for entropy, homogeneity, and GLCM-based features.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of the Geometry of the Distal Femur and Proximal Tibia in the Osteoarthritic Knee: A 3D Reconstruction CT Scan Based Study of 449 Cases

    Background: The aim of this study is to evaluate the geometry of the distal femur and the proximal tibia in the osteoarthritic knee using 3D reconstructive CT scan imaging. Methods: 449 patients with knee osteoarthritis were treated surgically in our center with patient-specific technology total knee arthroplasty. Preoperatively, all the patients underwent a CT scan according to a standard ...

متن کامل

Comparative Analysis of Intra-and Inter Populational Heterogeneity of the Essential Oils in White Savory Plants

White savory(Satureja mutica Fisch & C.A.Mey.) is one of the most widely used medicinal plants in food processing, pharmaceutical and cosmetic industry due to the strongly scented and presence of phenolic compounds such as carvacrol and thymol. This experiment was carried out to evaluate the levels of inter and intra-populations variability of essential oil compositions of S. mutica grown in no...

متن کامل

Comparison of a Segmentation Algorithm to Six Expert Imagiologists in Detecting Pulmonary Contours on X-ray CT Images

Quantitative evaluation of the performance of segmentation algorithms on medical images is crucial before their clinical use can be considered. We have quantitatively compared the contours obtained by a pulmonary segmentation algorithm to contours manually-drawn by six expert imaiologists on the same set of images, since the ground truth is unknown. Two types of variability (inter-observer and ...

متن کامل

The influence of using different reconstruction algorithms on sensitivity of quantitative 18F-FDG-PET volumetric measures to background activity variation

Introduction: This study aims to investigate the influence of background activity variation on image quantification in differently reconstructed PET/CT images. Methods: Measurements were performed on a Discovery-690 PET/CT scanner using a custom-built NEMA-like phantom. A background activity level of 5.3 and 2.6 kBq/ml 18F-FDG were applied. Ima...

متن کامل

داده‌کاهی و آنالیز تصاویر چند باندی نوری بلازار 180 Mrk

 Nearly simultaneous multiband monitoring of blazars is very limited and most studies reported in literature are conflicting, too. Although optical variability on intra-night timescales is now a well established phenomenon for blazars, its relationship to long-term variability remains unclear. Possible clues could come from monitoring the optical spectrum for correlation with brightness. The pr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016