Re-Erosion of Patch Graft of Ahmed Glaucoma Valve after Simple Conjunctival Closure: What Next?

نویسندگان

  • Avik Kumar
  • Harika Mudunuri
چکیده

Ahmed Glaucoma Valve Implantation is an important armamentarium in the management of refractory glaucoma like pseudophakic glaucoma in pediatric age group [1]. Though effective, complications are not uncommon [2,3]. However conjunctival dehiscence is relatively rare and previously has not been reported in this age group. Here we present a case of failed repair of conjunctival dehiscence over corneal patch graft which was managed with conservative therapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Management of implant plate exposure of silicone Ahmed glaucoma valve: a review of six cases

Objective: To describe the management options for exposed silicone Ahmed glaucoma valve (AGV) implant. Methods: This was carried out as a retrospective chart review at a tertiary care eye hospital in Southern India. Medical records of six subjects managed for AGV exposure from 2006 to 2013 were reviewed. Results: All six eyes had explantation of the AGV and 3 of them had reimplantation in a dif...

متن کامل

Conjunctival inclusion cyst following repair of tube erosion in a child with aphakic glaucoma, leading to endophthalmitis

INTRODUCTION Glaucoma in aphakia is a major long term complication following congenital cataract surgery. Implantation of glaucoma drainage device provides an effective approach to manage refractory paediatric glaucoma. However implant surgery in young individuals is not free of complications. The prompt detection and management of tube erosion is of utmost importance to prevent devastating seq...

متن کامل

Outcomes of using a sutureless bovine pericardial patch graft for Ahmed glaucoma valve implantation.

OBJECTIVE To evaluate the long-term outcomes of a surgical technique using a sutureless bovine pericardial patch graft for the implantation of an Ahmed glaucoma valve (AGV). 
 METHODS This was a pilot study on patients with primary open-angle glaucoma refractory to repeated surgical filtering procedures. All patients underwent AGV implant technique using a sutureless bovine pericardial patch ...

متن کامل

Partial thickness corneal tissue as a patch graft material for prevention of glaucoma drainage device exposure.

BACKGROUND To protect from erosion of the tube in glaucoma drainage device (GDD), the tube is covered by a biologic tissue which is roofed by the conjunctiva. Sclera, pericardium, dura mater and cornea are available as a patch graft. Drawbacks of some of these materials may include high cost and poor appearance. The purpose of this study is to report the long-term outcomes of partial thickness ...

متن کامل

Late-Onset Endophthalmitis Secondary to Exposed Glaucoma Tube Implant in a Rare Case of Paediatric Glaucoma

Glaucoma drainage implants (GDIs) are used to treat paediatric glaucoma resistant to conventional medical and surgical treatment, achieving good intraocular pressure (IOP) control and long-term success. Late endophthalmitis is a rare complication that may develop following GDI surgery. A 17-year-old male presented with acute endophthalmitis 2 years after Ahmed glaucoma valve implantation with p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016