Postoperative exercise tolerance after aortic valve replacement by small-size prosthesis: functional consequence of small-size aortic prosthesis.
نویسندگان
چکیده
OBJECTIVES The objective of this study was to determine whether a small-size valve prosthesis contributes to exercise intolerance, as assessed by VO2 measurement during an exhaustive cycle ergometer exercise. BACKGROUND The determinants of exercise capacity after mechanical aortic replacement are not well known. The selection of small valve sizes has, however, been described as an independent predictor of exercise intolerance as assessed by exercise duration. Maximal oxygen uptake (VO2max) is a good index of exercise tolerance. METHODS Fourteen patients were eligible, with a mean age of 62 +/- 6 years. Before surgery, the mean left ventricular ejection fraction (LVEF) was 73 +/- 8%. Two valve types with small diameter (19 to 21 mm) were used: Medtronic Hall and St Jude Medical. A healthy sedentary control group (n = 14) paired for age, weight and size was constituted. After one year of follow-up, cardiorespiratory tests were performed. In addition, the gradients through the prostheses were determined by continuous pulse Doppler at rest and immediately after the cardiorespiratory test. RESULTS The exercise tolerance was not significantly different between the control group and patient group: VO2 peak (21.7 vs. 20.4 ml/kg/min; p = 0.42), workloads (115 vs. 93 W; p = 0.13) and ventilatory parameters were similar. The mean and peak gradients at rest and during exercise were not correlated with VO2max. CONCLUSIONS Valve replacement by small aortic prosthesis does not seem to be a factor of exercise intolerance as assessed by VO2max in patients without LVEF dysfunction before surgery.
منابع مشابه
Aortic Valve replacement with Reduction Aortoplasty with Mesh Prosthesis in 75 years old with Sever aortic Regurgitation with Aortic Aneurysm
Although classic and standard procedure for patients with ascending Aorta aneurysm with Sever aortic Regurgitation is Bentall surgery but in some selected cases this complex surgery was not performed with different reason like advanced age and coexisting comorbidity involving renal and hepatic and lung Function. In our cases 75 years old man with chronic renal failure ( Cr= 3.2 ) who was known ...
متن کاملAN INNOVATIVE SURGIC AL TECHNIQUE FOR CONTINUOUS SUTURING OF PROSTHESIS IN MITR AL VALVE REPL A CEMENT
Mitral valve replacement (MVR) is usually performed in two methods of running and interrupted suturing. In running method, the suturing of the valve is usually with some traction on the annulus and also there is a risk of aortic valve injury. This study was conducted to evaluate a new technique for suturing to avoid these complications and decrease the time of cardiac arrest. One hundred an...
متن کاملValve prosthesis-patient mismatch: clinical implications in Japanese patients.
Aortic valve replacement (AVR) improves survival in patients with severe aortic stenosis (AS). Following recent advances in Doppler echocardiography, detailed evaluation of results after AVR is now based not only on the degree of alleviation of symptoms but also the degree of functioning of the prosthetic valve and the heart after surgery. Selection of a prosthetic valve is now viewed as an imp...
متن کاملمقایسه اندازه دریچه آئورت مصنوعی نصب شده با قطر رینگ دریچه آئورت به طریقه اکوکاردیوگرافی دو بعدی بمنظور پیش بینی اندازه دریچه مصنوعی آئورت قبل از عمل جراحی
In recent socio-economic state it is not possible to have different sets of prosthetic cardiac valves available in the operating room before open-heart surgery for valvular replacement. In this study the diameter of the aortic valve ring measured in 2-D echocardiography was compared with the size of the aortic prosthetic valves implanted for the patients with aortic valvular disease. The purpos...
متن کاملSevere aortic stenosis with low transvalvular gradient and severe left ventricular dysfunction:result of aortic valve replacement in 52 patients.
BACKGROUND The outcome of aortic valve replacement in patients with severe aortic stenosis, low transvalvular gradient, and severe left ventricular dysfunction is not well known. METHODS AND RESULTS Between 1985 and 1995, 52 patients with left ventricular ejection fraction (EF) < or =35% and aortic stenosis with transvalvular mean gradient <30 mm Hg underwent aortic valve replacement. The mea...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Cardiology
دوره 36 3 شماره
صفحات -
تاریخ انتشار 2000