Analysis of trace atrazine and simazine in environmental samples by liquid chromatography-fluorescence detection with pre-column derivatization reaction.
نویسندگان
چکیده
Coupled with off-line extraction, a pre-column derivatization liquid chromatographic fluorescence detection (LC-FL) procedure was developed for the determination of atrazine and simazine in soil, crop and water samples. Concentrations in real samples were expected to be at or below the low ng/g level, which requires pre-concentration of analytes and improved detection. 4-(2-Phthalimidyl) benzoyl chloride (PIB-Cl) was used as a pre-column derivation reagent for high-performance liquid chromatography. The clean-up and second-time concentration procedures, which were indispensable in the conventional analytical methods for soil and crop analysis because of the complexity of the samples, were replaced by a derivatization reaction between PIB-Cl and the analytes. The fluorescent and ultraviolet characteristics of the derivatives were investigated. The derivatization reaction and chromatographic separation conditions were optimized systematically. Detection limits of 1.2 ng/g for atrazine and 1.1 ng/g for simazine were obtained with recoveries of 84-95% for environmental samples. On the basis of practical application to five soil and five crop samples, the LC-FL method was compared with the conventional GC-MS method.
منابع مشابه
High Performance Liquid Chromatography Coupled with Pre-column Derivatization for Determination of Oxidized Glutathione Level in Rats Exposed to Paraquat
Glutathione (GSH) is one of the most important antioxidants that plays an essential role in detoxification of reactive oxygen species (ROS) which oxidizes to glutathione disulfide (GSSG). Paraquat (PQ), awidely used herbicide, causes pulmonary injury with the productionof ROS. Excessive ROS accumulation as a consequence of PQ exposure are frequently targeted by GSH thereby oxidative stress lead...
متن کاملHigh Performance Liquid Chromatography Coupled with Pre-column Derivatization for Determination of Oxidized Glutathione Level in Rats Exposed to Paraquat
Glutathione (GSH) is one of the most important antioxidants that plays an essential role in detoxification of reactive oxygen species (ROS) which oxidizes to glutathione disulfide (GSSG). Paraquat (PQ), awidely used herbicide, causes pulmonary injury with the productionof ROS. Excessive ROS accumulation as a consequence of PQ exposure are frequently targeted by GSH thereby oxidative stress lead...
متن کاملA Sensitive Liquid Chromatographic Method for the Analysis of Clarithromycin with Pre-Column Derivatization: Application to a Bioequivalence Study
Objective(s) A sensitive liquid chromatographic method for the analysis of clarithromycin- a macrolide antibiotic- in human serum, using pre-column derivatization with 9-fluorenylmethyl chloroformate (FMOC-Cl) is described. Materials and Methods The method involved liquid-liquid extraction of the drug and an internal standard (amantadine) followed by pre-column derivatization of the analytes...
متن کاملUltrasound Assisted Emulsification Microextraction as a Simple Preconcentration Method for Determination of Atrazine in Environmental Samples
We represent an environmentally friendly sample of pre-treatment method, ultrasound assisted emulsification microextraction (USAEME) followed by gas chromatography nitrogen phosphorous detector (GC-NPD), to specify atrazine residues in environmental samples. Some parameters affecting the extraction efficiency such as the type and volume of the extraction solvent, emulsification time and additio...
متن کاملDevelopment and optimization of a method for the determination of simazine, atrazine and propazine using solid-phase extraction and HPLC/GC
A solid-phase extraction (SPE) method, coupled with HPLC/DAD and GC/FID analysis has been developed for the simultaneous determination of simazine, atrazine and propazine in water samples. The compounds of interest were enriched on Envi-carb SPE tubes. The recoveries for simazine, atrazine and propazine from spiked Nanopure water were 101 5.6 %, 99 4.9 % and 96 5.7 %, respectively. The detectio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of chromatography. A
دوره 827 1 شماره
صفحات -
تاریخ انتشار 1998