Correcting spherical aberrations in a biospecimen using a transmissive liquid crystal device in two-photon excitation laser scanning microscopy.

نویسندگان

  • Ayano Tanabe
  • Terumasa Hibi
  • Sari Ipponjima
  • Kenji Matsumoto
  • Masafumi Yokoyama
  • Makoto Kurihara
  • Nobuyuki Hashimoto
  • Tomomi Nemoto
چکیده

Two-photon excitation laser scanning microscopy has enabled the visualization of deep regions in a biospecimen. However, refractive-index mismatches in the optical path cause spherical aberrations that degrade spatial resolution and the fluorescence signal, especially during observation at deeper regions. Recently, we developed transmissive liquid-crystal devices for correcting spherical aberration without changing the basic design of the optical path in a conventional laser scanning microscope. In this study, the device was inserted in front of the objective lens and supplied with the appropriate voltage according to the observation depth. First, we evaluated the device by observing fluorescent beads in single- and two-photon excitation laser scanning microscopes. Using a 25× water-immersion objective lens with a numerical aperture of 1.1 and a sample with a refractive index of 1.38, the device recovered the spatial resolution and the fluorescence signal degraded within a depth of 0.6 mm. Finally, we implemented the device for observation of a mouse brain slice in a two-photon excitation laser scanning microscope. An optical clearing reagent with a refractive index of 1.42 rendered the fixed mouse brain transparent. The device improved the spatial resolution and the yellow fluorescent protein signal within a depth of 0-0.54 mm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transmissive liquid-crystal device for correcting primary coma aberration and astigmatism in biospecimen in two-photon excitation laser scanning microscopy.

All aberrations produced inside a biospecimen can degrade the quality of a three-dimensional image in two-photon excitation laser scanning microscopy. Previously, we developed a transmissive liquid-crystal device to correct spherical aberrations that improved the image quality of a fixed-mouse-brain slice treated with an optical clearing reagent. In this study, we developed a transmissive devic...

متن کامل

Two-photon microscopy with wavelength switchable fiber laser excitation.

Two-photon scanning fluorescence microscopy has become a powerful tool for imaging living cells and tissues. Most applications of two-photon microscopy employ a Ti:sapphire laser excitation source, which is not readily portable or rapidly tunable. This work explores the use of two-photon fiber laser excitation (TP-FLEX) as an excitation source for scanning two-photon microscopy. We have further...

متن کامل

Adaptive optics two photon scanning laser fluorescence microscopy

Two-photon fluorescence microscopy provides a powerful tool for deep tissue imaging. However, optical aberrations from illumination beam path limit imaging depth and resolution. Adaptive Optics (AO) is found to be useful to compensate for optical aberrations and improve image resolution and contrast from two-photon excitation. We have developed an AO system relying on a MEMS Deformable Mirror (...

متن کامل

Two-versus one photon excitation laser scanning microscopy: critical importance of excitation wavelength.

It is often anticipated that two-photon excitation (TPE) laser scanning microscopy should improve cell survival and tissue penetration relative to conventional one-photon excitation (OPE) confocal scanning laser microscopy (CLSM). However few studies have directly compared live cell imaging using one- vs two-photon laser scanning microscopy. We have used calcein-loaded in situ chondrocytes with...

متن کامل

Adaptive correction of depth-induced aberrations in multiphoton scanning microscopy using a deformable mirror.

We demonstrate adaptive aberration correction for depth-induced spherical aberration in a multiphoton scanning microscope with a micromachined deformable mirror. Correction was made using a genetic learning algorithm with two-photon fluorescence intensity feedback to determine the desired shape for an adaptive mirror. For a 40x/0.6 NA long working distance objective, the axial scanning range wa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomedical optics

دوره 20 10  شماره 

صفحات  -

تاریخ انتشار 2015