Classification of cell types using a microfluidic device for mechanical and electrical measurement on single cells.

نویسندگان

  • Jian Chen
  • Yi Zheng
  • Qingyuan Tan
  • Ehsan Shojaei-Baghini
  • Yan Liang Zhang
  • Jason Li
  • Preethy Prasad
  • Lidan You
  • Xiao Yu Wu
  • Yu Sun
چکیده

This paper presents a microfluidic system for cell type classification using mechanical and electrical measurements on single cells. Cells are aspirated continuously through a constriction channel with cell elongations and impedance profiles measured simultaneously. The cell transit time through the constriction channel and the impedance amplitude ratio are quantified as cell's mechanical and electrical property indicators. The microfluidic device and measurement system were used to characterize osteoblasts (n=206) and osteocytes (n=217), revealing that osteoblasts, compared with osteocytes, have a larger cell elongation length (64.51 ± 14.98 μm vs. 39.78 ± 7.16 μm), a longer transit time (1.84 ± 1.48 s vs. 0.94 ± 1.07 s), and a higher impedance amplitude ratio (1.198 ± 0.071 vs. 1.099 ± 0.038). Pattern recognition using the neural network was applied to cell type classification, resulting in classification success rates of 69.8% (transit time alone), 85.3% (impedance amplitude ratio alone), and 93.7% (both transit time and impedance amplitude ratio as input to neural network) for osteoblasts and osteocytes. The system was also applied to test EMT6 (n=747) and EMT6/AR1.0 cells (n=770, EMT6 treated by doxorubicin) that have a comparable size distribution (cell elongation length: 51.47 ± 11.33 μm vs. 50.09 ± 9.70 μm). The effects of cell size on transit time and impedance amplitude ratio were investigated. Cell classification success rates were 51.3% (cell elongation alone), 57.5% (transit time alone), 59.6% (impedance amplitude ratio alone), and 70.2% (both transit time and impedance amplitude ratio). These preliminary results suggest that biomechanical and bioelectrical parameters, when used in combination, could provide a higher cell classification success rate than using electrical or mechanical parameter alone.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fluorescent Contrast agent Based on Graphene Quantum Dots Decorated Mesoporous Silica Nanoparticles for Detecting and Sorting Cancer Cells

Background and Objectives: The inability of classic fluorescence-activated cell sorting to single cancer cell sorting is one of the most significant drawbacks of this method. The sorting of cancer cells in microdroplets significantly influences our ability to analyze cancer cell proteins. Material and Methods: We adapted a developed microfluidic device as a 3D in vitro model to sorted MCF-7 c...

متن کامل

Development of Microfluidic Device with Movable Electrode for Electrical Impedance Measurement on the Actively Compressed Single Cell

ABSTRACT We develop a microfluidic device which can measure the electrical properties of the actively compressed cell. When compared with the previous passive cell compression device, the proposed microfluidic device can provide the active cell compression via the movable(sliding) electrode. Cell’s direct contact with the electrodes can reduce the noise and produce the pure physiological inform...

متن کامل

طراحی و ساخت سیستم میکروفلوییدی و ارزیابی قابلیت آن جهت تولید اینترلوکین 2 توسط سلول های جورکت

Background and purpose: Microfluidic systems are microstructures that could be used to improve the conventional cell culture protocols used in laboratories. The aim of this research was to design and construct the microfluidic system and evaluating its ability to produce IL-2 by jurkat cells. Material and methods: At first, the sketch of microfluidic canals was designed by Corel draw and wa...

متن کامل

Classification of Cell Types Using Mechanical and Electrical Measurement on Single Cells

This paper presents a microsystem for single-cell characterization by aspirating cells continuously through a constriction channel while cell impedance profiles and images are measured to quantify transit time, the impedance amplitude ratio, and cell elongation simultaneously. The system demonstrated that osteoblasts, compared with osteocytes, have a larger cell elongation length, longer transi...

متن کامل

Capture and enumeration of mRNA transcripts from single cells using a microfluidic device.

Accurate measurement of RNA transcripts from single cells will enable the precise classification of cell types and characterization of the heterogeneity in cell populations that play key roles in normal cellular physiology and diseases. As a step towards this end, we have developed a microfluidic device and methods for automatic hydrodynamic capture of single mammalian cells and subsequent immo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lab on a chip

دوره 11 18  شماره 

صفحات  -

تاریخ انتشار 2011