The value of transvaginal ultrasound to monitor the position of an intrauterine device after insertion. A technology assessment study.

نویسندگان

  • C D de Kroon
  • J C van Houwelingen
  • J B Trimbos
  • F W Jansen
چکیده

BACKGROUND The intrauterine device (IUD) is an effective contraceptive method. The contraceptive power as well as the side-effects of IUD are thought to relate to the position of the IUD in the uterine cavity. We assessed the accuracy of clinical evaluation of IUD position. METHODS A prospective comparative study was performed. The clinical evaluation was compared with the TVU measurement of IUD position both immediately after insertion and 6 weeks after insertion. The primary outcome measures were the positive and negative predictive values (PPV and NPV) of the clinical evaluation of IUD position. RESULTS 195 women were included consecutively, 181 women (92.8%) were available for follow-up. The PPV and NPV of clinical evaluation of IUD position immediately after insertion were respectively 0.60 (95% CI: 0.39-0.81) and 0.98 (95% CI: 0.96-1.0). The prevalence of an abnormally positioned IUD was 7.7% (95% CI: 3.9-11.4). The PPV and NPV of the clinical evaluation at follow-up were respectively 0.54 (95% CI: 0.26-0.81) and 1.0 (95% CI: 0.98-1.0). The prevalence of abnormal position was 4.0% (95% CI: 1.7-7.1). CONCLUSION Clinical evaluation is an excellent test for the evaluation of the position of an IUD and routine TVU is not indicated for this purpose.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Role of Three Dimensional Transvaginal Ultrasound in Detection of Intrauterine Device Displacement in Post Caesarean Section: A Case Report

Intrauterine Devices (IUDs) are used as an efficient and inexpensive method of contracep¬tion. Contraceptive efficacy depends on the intrauterine location of IUD and intrauterine displacement of the IUD leads to decreased contraceptive efficacy. Expulsion of IUD and its penetration into myometrium is one of the complications of IUD. In cases where IUDs are not detected by ultrasound method, in ...

متن کامل

Partial and complete expulsion of the Multiload 375 IUD and the levonorgestrel-releasing IUD after correct insertion.

OBJECTIVE The contraceptive efficacy of intrauterine devices (IUD) is thought to relate to the position of the IUD in the uterine cavity. Several trials examined the number of copper IUD expulsions, but none evaluated the partial and complete expulsion rate of the levonorgestrel-releasing device (LNG-IUD). STUDY DESIGN This retrospective cohort study compares the dislocation rate of the Multi...

متن کامل

P-45: Predictive Value of Follicular Fluid VitaminD on Assisted Reproductive TechniqueOutcome

Background: Vitamin D, a steroid hormone, has critical roles in human health. The available data thus identify vitamin D as an important substance in processes involved in reproductive success and thereby suggest pathophysiological mechanisms for reproductive compromise in the setting of vitamin D deficiency. Realizing the prevalence of vitamin D insufficiency in our country, we hypothesized th...

متن کامل

Does Uterine Artery Doppler or Copper Intrauterine Device Location by Three Dimensional Transvaginal Ultrasound Correlates with Clinical Symptoms?

Aim of study: To evaluate the effectiveness of using uterine artery color Doppler and location of intrauterine copper device by three dimensional transvaginal ultrasound in relation to abnormal vaginal bleeding and pain. Methods: Three dimensional transvaginal ultrasound examinations were carried out to 180 women 3-6 months after IUD insertion. Seventy six women were suffering from pain (groupI...

متن کامل

I-25: Management of Hydrosalpinx in ART

Hydrosalpinx, is one of the severe manifestations of tubal disease, is associated with significantly lower implantation and pregnancy rates, increased spontaneous abortion and ectopic pregnancy.This condition is usually due to PID but may also result from peritonitis of any cause or tubal damage from previous surgery.The mechanism for poor outcome in patients undergoing IVF is not yet clear. Ma...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Human reproduction

دوره 18 11  شماره 

صفحات  -

تاریخ انتشار 2003