Mixed venous oxygen saturation in critically ill septic shock patients. The role of defined events.
نویسندگان
چکیده
STUDY OBJECTIVE To investigate the frequency and extent of spontaneous changes ("events") in continuously measured mixed venous oxygen saturation (SvO2) in septic patients and to determine whether attention to individual event-frequency offers additional information for patient management. DESIGN Nonrandomized prospective study. SETTING General intensive care unit at a university hospital. PATIENTS Fifteen patients suffering from septic shock and multiple organ dysfunction syndrome. MEASUREMENTS For the continuous assessment of SvO2 a fiberoptic pulmonary artery catheter (Baxter Edwards) was inserted in all patients. A certain event was defined as a sudden change in SvO2 of > or = 5 percent lasting for > 10 min. All events were grouped as either moderate (< or = 10 percent changes in SvO2) or severe events (> 10 percent changes). Hemodynamics and inotropic support, oxygenation and ventilatory support, hemoglobin levels and body temperature were determined at the event and compared with the ultimate values registered before the event. RESULTS We evaluated 377 events during an observation period of 1,575 h. Patients' mean SvO2 levels ranged between 72 +/- 7 and 82 +/- 4. Desaturations below 65 percent (39 out of 377 events) occurred in 11 patients. Overall, 74 percent of all events were moderate and 26 percent were severe. The incidence of events was 5.6 +/- 1.5 during 24 h in survivors (n = 10) and 6.3 +/- 1.6 during 24 h in nonsurvivors (n = 5). While in survivors only 20 percent of all events were severe events, this portion was significantly higher in nonsurvivors (34 percent; p = 0.03). In 67 percent of all events we observed changes in the registered physiologic parameters or therapeutic interventions probably causing the event. The cause of the remaining 33 percent of all events could not be elucidated. CONCLUSIONS The SvO2 of septic shock patients is mainly normal or even supranormal. However, short-term changes in SvO2 do occur frequently in these patients. Nonsurvivors exhibit a higher frequency as well as a significantly greater severity of events, which may point toward a concealed mismatch of oxygen supply and demand. A high incidence of short-term SvO2 changes in a septic shock patient may be of diagnostic and prognostic significance. Therefore, we recommend the installation of a computerized alarm-function for the automatic detection and indication of frequent events.
منابع مشابه
The value of venous oximetry.
PURPOSE OF REVIEW Maintenance of adequate tissue oxygenation is an important task in intensive care units. In this context, venous oximetry by obtaining mixed venous oxygen saturation or central venous oxygen saturation has been discussed as useful monitoring parameters. This review discusses the physiology and clinical application of these parameters. RECENT FINDINGS No study has so far demo...
متن کاملThe incidence of low venous oxygen saturation on admission to the intensive care unit: a multi-center observational study in The Netherlands
BACKGROUND Low mixed or central venous saturation (S(c)vO2) can reveal global tissue hypoxia and therefore can predict poor prognosis in critically ill patients. Early goal directed therapy (EGDT), aiming at an ScvO2 >/= 70%, has been shown to be a valuable strategy in patients with sepsis or septic shock and is incorporated in the Surviving Sepsis Campaign guidelines. METHODS In this prospec...
متن کاملHigh mixed venous oxygen saturation levels do not exclude fluid responsiveness in critically ill septic patients
INTRODUCTION The aim of this study was to determine whether the degree of fluid responsiveness in critically ill septic patients is related to baseline mixed venous oxygen saturation (SvO2) levels. We also sought to define whether fluid responsiveness would be less likely in the presence of a high SvO2 (>70%). METHODS This observational study was conducted in a 32-bed university hospital medi...
متن کاملCritical Assessment of Use of Central Venous Oxygen Saturation as a Mirror of Mixed Venous Oxygen in Severely Ill Cardiac Patients By MELVIN
Bedside catheterization of the right heart with a percutaneously introduced flowdirected catheter was carried out in 24 critically ill patients; 71 determinations of mixed venous oxygen saturation (MVo2) were obtained. A second catheter was inserted either into a central intrathoracic vein or the right atrium for simultaneous sampling of central venous (CVo2) or right atrial (RAo2) oxygen satur...
متن کاملFluid therapy for septic shock resuscitation: which fluid should be used?
Early resuscitation of septic shock patients reduces the sepsis-related morbidity and mortality. The main goals of septic shock resuscitation include volemic expansion, maintenance of adequate tissue perfusion and oxygen delivery, guided by central venous pressure, mean arterial pressure, mixed or central venous oxygen saturation and arterial lactate levels. An aggressive fluid resuscitation, p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Chest
دوره 103 3 شماره
صفحات -
تاریخ انتشار 1993