Accuracy of the Double Variation Technique of Refractive Index Measurement

نویسندگان

  • Jennifer R. Verkouteren
  • Eric B. Steel
  • Eric S. Windsor
  • John M. Phelps
چکیده

Errors in the double variation teclinique of refractive index measurement are analyzed using a new approach. The ability to measure matching wavelength is characterized, along with the effect on the calculated refractive index. Refractive index accuracy and precision are very dependent on the specifics of each calibration set, particularly the difference in dispersion between the liquid and solid. Our best precision (±1 or 2×10-4) is attained only when the difference in dispersion between liquid and solid is small, and is dependent on an individual operator's ability to perceive changes in relief. This precision is impossible to achieve for the other glass/liquid combinations, where we are limited by a precision of approximately 1 nm in the selection of matching wavelength. A bias in the measurement of matching wavelength exists that affects the accuracy of the calculated refractive indices. The magnitude of the bias appears to be controlled by the bandpass of the graded interference filter. The errors in refractive index using a graded interference filter with a bandpass of 30 nm FWHM (full width at half maximum intensity) are an order of magnitude larger than the errors using a filter with a bandpass of 15 nm FWHM.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement and comparison of the temperature-dependence of refractive index of water and Plexiglas phantoms by interferometry method for their use in optical calorimetry

In radiation calorimetry by using laser beams and interferometry setups, variations induced by dose absorption in phantom can be precisely measured. Dose absorption and the induced temperature change result in refractive index variation of the material. In order to be able to measure the low amount of absorbed dose in the phantom, temperature dependence of refractive index of the material must ...

متن کامل

Modeling of measurement error in refractive index determination of fuel cell using neural network and genetic algorithm

Abstract: In this paper, a method for determination of refractive index in membrane of fuel cell on basis of three-longitudinal-mode laser heterodyne interferometer is presented. The optical path difference between the target and reference paths is fixed and phase shift is then calculated in terms of refractive index shift. The measurement accuracy of this system is limited by nonlinearity erro...

متن کامل

اندازه‌گیری ضریب شکست غیر خطی در شیشه‌های آلاییده به بلورهای نیمرسانا

  There are several techniques in use for non-linear refractive index measurement, namely, interferometric techniques, in which conventional inter-ferometers are used, degenerate for wave mixing (DFWM), and z-scan, Each of these techniques suffers from some shortcmings. For example conventional interferometers like Fabry-Perot and Twyman-Green need high quality optical components, unwanted refl...

متن کامل

اندازه‌گیری همزمان ضریب شکست و ضخامت فیزیکی دستگاه‌های چندلایه‌ای با استفاده از نتایج مقطع‌نگاری همدوسی اپتیکی در فضای فوریه

In fourier domain optical coherence tomography, we can measure the optical thickness ( refractive index n times thickness d), to obtain the retinal layers in order to diagnose many disorders. In this work, we introduce a new method for measurement of refractive index and physical thickness of multiple layers simultaneously by Fourier domain optical coherence tomography, without additional infor...

متن کامل

Measuring the temperature dependence of refractive index in water phantom for precise monitoring of the absorbed dose by radiation therapy techniques

In this paper, an experimental setup is used to measure the temperature dependence of the refractive index of a water phantom. In radiation calorimetry by laser beams and interferometric systems, the amount of change induced by radiation within the phantom can be accurately measured. Absorption of dose and the resulted change in temperature changes the refractive index within the material. In o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 97  شماره 

صفحات  -

تاریخ انتشار 1992