BACKGROUND Previous methods to measure glycohemoglobin (GHb) have been time-consuming or imprecise; we therefore developed a new enzymatic assay for GHb. METHODS Blood cells were first hemolyzed, and hemoglobin was digested with protease to yield fructosyl amino acid. Fructosyl amino acid oxidase acts on the fructosyl amino acid and generates hydrogen peroxide, which reacts with chromogens in the presence of peroxidase. Total hemoglobin was measured spectrometrically in the same reaction tube. The results were reported as the ratio of the concentrations of GHb and hemoglobin. RESULTS The measured values were comparable to those determined with a HPLC method and with an immunoassay in blood samples from 2854 patients with diabetes. Regression analysis for the enzymatic assay (y) vs the HPLC method (x) produced the following: r = 0.979; slope, 0.994 [95% confidence interval (CI), 0.986-1.001]; y-intercept, 0.04% (95% CI, -0.09% to 0.01%); n = 2854. For the enzymatic assay (y) vs the immunoassay (x), the regression statistics were as follows: r = 0.982; slope, 1.002 (95% CI, 0.995-1.009); y-intercept, 0% (95% CI, -0.05% to 0.05%); n = 2854. CONCLUSIONS The values measured by the new enzymatic assay are sufficiently correlated with those of the conventional HPLC method and immunoassay, but the proposed assay for GHb is rapid and has high precision.
منابع مشابه
Fully automated assay of glycohemoglobin with the Abbott IMx analyzer: novel approaches for separation and detection.
We describe a novel assay for measuring glycohemoglobin directly from anticoagulated whole blood with the Abbott IMx analyzer. The glycohemoglobin is labeled with a soluble polyanionic affinity reagent and the anionic complex is then captured with a cationic solid-phase matrix. Glycohemoglobin is quantified by measuring the quenching by heme of the static fluorescence from an added fluorophore....
متن کاملNew Enzymatic Colorimetric Method for the Quantitative Determination of Phenylalanine in Dry-Blood Spots
Phenylketonuria (PKU) is an autosomal recessive disorder, which is characterized by severe mental retardation, microcephaly and seizures. The symptoms of this disease can be prevented if detected soon after birth. Therefore, blood Phenylalanine (Phe) measurement is essential for the early diagnosis, treatment and dietary monitoring of PKU patients. The goal of this research was to introduce a r...
متن کاملNon-separation assay for glycohemoglobin.
The determination of glycohemoglobin [HbA1c, HbA1, or total glycohemoglobin (GHb)] has become an established procedure in the management of diabetes mellitus. Here, we describe the development of a simple, fluorescence, non-separation assay for the percentage of GHb (%GHb). The fluorescence of an eosin-boronic acid derivative when it was mixed with hemolysates of unwashed erythrocytes was quenc...
متن کاملChronic lymphocytic leukemia cells may interfere in a glycated hemoglobin assay based on fluorescence quenching.
Recently, we observed falsely low results by the Abbott IMx Glycated Hemoglobin assay apparently caused by a high number of leukocytes in patients with chronic lymphocytic leukemia. Because chronic lymphocytic leukemia and diabetes mellitus (monitored by glycohemoglobin measurements) occur more frequently in the elderly, we examined this interference further. The IMx Glycated Hemoglobin assay (...
متن کاملIncreased fetal hemoglobin in insulin-treated diabetes mellitus contributes to the imprecision of glycohemoglobin measurements.
An increased prevalence of fetal hemoglobin (HbF) has been described in pediatric insulin-dependent patients. The popular electroendosmotic method for glycohemoglobin includes HbF. In an adult population comprising 50 insulin-treated and 57 non-insulin-treated diabetic patients and 57 control subjects, we measured HbF by HPLC and measured glycohemoglobin by both HPLC and an electroendosmotic me...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 49 2 شماره
صفحات -
تاریخ انتشار 2003