Research on an anti-motion interference algorithm of blood oxygen saturation based on AC and DC analysis.
نویسندگان
چکیده
BACKGROUND There is an urgent need for blood oxygen saturation (SpO2) tests when participants are ambulatory, as in daily activity monitoring, sleep monitoring, or even athletes' cardiovascular function tests. In such situations, measuring equipment needs to be wearable. This restricts the processor volume, and the corresponding algorithm should be microprocessor compatible. OBJECTIVE This article proposes an anti-motion interference blood oxygen saturation algorithm for the microcontroller based on AC and DC analysis, named de-trended FFT. METHODS An experiment was conducted to compare the de-trended FFT algorithm with two other algorithms commonly used in the time and frequency domains. In the experiment, participants' oxygen saturation levels were calculated from Photoplethysmography (PPG) signals that were recorded continuously. Meantime, five types of hand motions were conducted, including hand trembling movements, horizontal hand movements, vertical hand movements, finger tapping, and finger bending, with each state lasting 2 minutes. RESULTS Results show significant performance of de-trended FFT in SpO2 calculation (P < 0.05), in both accuracy and stability. CONCLUSION De-trended FFT stands out in both mean deviation and variance by eliminating trending influence when compared with the other two algorithms. The motion interference's influence on SpO2 calculation mainly comes from the AC component, not the DC.
منابع مشابه
Analysis of Frequency Leakage in Different Optical Paths of Nano-Metrology Systems Based on Frequency-Path Models
The drawing of frequency-path (F-P) models of optical beams is an approach for nonlinearity analysis in nano-metrology systems and sensors based on the laser interferometers. In this paper, the frequency-path models of four nano-metrology laser interferometry systems are designed, analyzed and simulated, including ...
متن کاملComparing the Effect of Simple Filtration Hemodialysis and Ultrafiltration Hemodialysis on Arterial Oxygen Saturation and Blood Pressure in Chronic Dialysis
Background and purpose: Hypoxemia and hypotension are important complications of hemodialysis in patients with chronic renal failure that are linked to several factors, including the type of filters used. The aim of this study was to compare the effect of simple filtration hemodialysis and ultrafiltration hemodialysis on blood pressure and blood arterial oxygen level. Materials and methods: In...
متن کاملA Single-Chip CMOS Pulse Oximeter with On-Chip Lock-In Detection
Pulse oximetry is a noninvasive and continuous method for monitoring the blood oxygen saturation level. This paper presents the design and testing of a single-chip pulse oximeter fabricated in a 0.35 µm CMOS process. The chip includes photodiode, transimpedance amplifier, analogue band-pass filters, analogue-to-digital converters, digital signal processor and LED timing control. The experimenta...
متن کاملNumerical Simulation of Blood Flow Mixed with Magnetic Nanoparticles under the Influence of AC and DC Magnetic Field
Nanoparticles combined with magnetic fields are one of the most important research areas in the field of biomedical engineering. Direct Current (DC) magnetic and Alternative Current (AC) magnetic fields are often used for controlling nanoparticles. It is also used for hyperthermia treatment. The purpose of the current study is to investigate the effect of DC and AC magnetic field on nanoparticl...
متن کاملDesign Optimization of Axial Flux Surface Mounted Permanent Magnet Brushless DC Motor For Electrical Vehicle Based on Genetic Algorithm
This paper presents the design optimization of axial flux surface mounted Permanent Magnet Brushless DC motor based on genetic algorithm for an electrical vehicle application. The rating of the motor calculated form vehicle dynamics is 250 W, 150 rpm. The axial flux surface mounted Permanent Magnet Brushless DC (PMBLDC) motor was designed to fit in the rim of the wheel. There are several design...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Technology and health care : official journal of the European Society for Engineering and Medicine
دوره 23 Suppl 2 شماره
صفحات -
تاریخ انتشار 2015