Effect of disposable infection control barriers on light output from dental curing lights.

نویسندگان

  • Barbara A Scott
  • Corey A Felix
  • Richard B T Price
چکیده

PURPOSE To prevent contamination of the light guide on a dental curing light, barriers such as disposable plastic wrap or covers may be used. This study compared the effect of 3 disposable barriers on the spectral output and power density from a curing light. The hypothesis was that none of the barriers would have a significant clinical effect on the spectral output or the power density from the curing light. METHODS Three disposable barriers were tested against a control (no barrier). The spectra and power from the curing light were measured with a spectrometer attached to an integrating sphere. The measurements were repeated on 10 separate occasions in a random sequence for each barrier. RESULTS Analysis of variance (ANOVA) followed by Fisher's protected least significant difference test showed that the power density was significantly less than control (by 2.4% to 6.1%) when 2 commercially available disposable barriers were used (p < 0.05). There was no significant difference in the power density when general-purpose plastic wrap was used (p > 0.05). The effect of each of the barriers on the power output was small and probably clinically insignificant. ANOVA comparisons of mean peak wavelength values indicated that none of the barriers produced a significant shift in the spectral output relative to the control ( p > 0.05). CONCLUSIONS Two of the 3 disposable barriers produced a significant reduction in power density from the curing light. This drop in power was small and would probably not adversely affect the curing of composite resin. None of the barriers acted as light filters.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the Effect of Protective Sleeve on Output Intensity of Light Emitting Diode Light Cure Units

Aim: The purpose of this study was to compare the difference in the output intensity of Light Emitting Diode (LED) light cure (LC) devices with and without a protective sleeve and its clinical significance.  Materials and Methods: The output intensity of 152 LC units in dental offices across the state of Odisha were examined. The collection of related information included an average number of e...

متن کامل

Effect of Light Curing Unit Characteristics on Light Intensity Output, Depth of Cure and Surface Micro-hardness of Dental Resin Composite.

BACKGROUND Modern dental composite restorations are wholly dependent on the use of Visible Light Curing devices. The characteristics of these devices may influence the quality of composite resin restorations. OBJECTIVE To determine the characteristics of light curing units (LCUs) in dental clinics in Nairobi and their effect on light intensity output, depth of cure (DOC) and surface micro-har...

متن کامل

Comparison of the Effect of Three LED Light Modes and Conventional QTH Curing Light on Shear Bond Strength of Composite to Dentin

  Objective: Shear bond strength is an important property inherent to the durability of tooth-colored restorative materials namely composite resins. It has been years that halogen light sources have been used for polymerization of composite resins. In recent years Light Emitting Diodes (LED) have been introduced for this purpose. With respect to their longer bulb life, needless of a filter and ...

متن کامل

The dental curing light: A potential health risk.

Powerful blue-light emitting dental curing lights are used in dental offices to photocure resins in the mouth. In addition, many dental personnel use magnification loupes. This study measured the effect of magnification loupes on the "blue light hazard" when the light from a dental curing light was reflected off a human tooth. Loupes with 3.5x magnification (Design for Vision, Carl Zeiss, and Q...

متن کامل

The Effect of Standard and Extended Curing Time in Different Distances on Composite’s Degree of Conversion

Introduction: The aim of this study was to in-vestigate the effect of irradiation duration and distance of light tip to prepared samples in two different light curing unites on the degree of conversion of resin composite. Materials and Methods: Conventional halogen and blue Light emitting diode (LED) units were used for polymerization of an Opalis resin com-posite. The conversion measurements w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal

دوره 70 2  شماره 

صفحات  -

تاریخ انتشار 2004