Prostate MRI and 3D MR spectroscopy: how we do it.

نویسندگان

  • Sadhna Verma
  • Arumugam Rajesh
  • Jurgen J Fütterer
  • Baris Turkbey
  • Tom W J Scheenen
  • Yuxi Pang
  • Peter L Choyke
  • John Kurhanewicz
چکیده

OBJECTIVE This review is a primer on the technical aspects of performing a high-quality MRI and MR spectroscopic imaging examination of the prostate. CONCLUSION MRI and MR spectroscopic imaging are useful tools in the localization, staging, and functional assessment of prostate cancer. Performing a high-quality MR spectroscopic examination requires understanding of the technical aspects and limitations of spectral acquisition, postprocessing techniques, and spectral evaluation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

MRI spectroscopy in screening of prostate cancer.

BACKGROUND The purpose of this study was to evaluate the suitability of MR Spectroscopy in screening for prostate cancer in comparison to T2-weighted MR imaging. MATERIALS AND METHODS Forty-six patients with biopsy confirmed prostate cancer underwent combined endorectal-body-phased-array MRI at 1.5T (Tesla). Twelve patients were additionally examined with 3D-spectroscopy sequence. The results...

متن کامل

Prostate Cancer Detection and Localization

Diffusion-weighted imaging (DWI) of the human with 1.5T MRI gives the insight of Prostate Cancer Tissue details. DWI is now used also for other Liver, Kidney, and Heart Imaging than the brain, and especially focused on detection of Cancer Tissues in prostate.1H-MR spectroscopy technique is used to detect and localize prostate cancer. One difficult sight of 1.5T prostate spectroscopy is the use ...

متن کامل

Dosimetric and Radiobiological Evaluation of Multiparametric MRI-guided Dose Painting in radiotherapy of Prostate Cancer

Introduction: Radiotherapy is one of the treatment options for locally advanced prostate cancer, however with standard radiation doses it is not always very effective. One of the strategies to improve the efficiency of radiotherapy is increasing the dose. In this study to increase tumor local control rates a new radiotherapy method, known as dose painting (DP) was investigated....

متن کامل

Optimization of clinical target volume delineation using magnetic resonance spectroscopic imaging (MRSI) in 3D conformal radiotherapy of prostate cancer

Background: For the purpose of individual clinical target volume assessment in radiotherapy of prostate cancer, MRSI was used as a molecular imaging modality with MRI and CT images. Materials and Methods: The images of 20 prostate cancer patients were used in this study. The MR and MRSI images were registered with CT ones using non-rigid registration technique. The CT based planning (BP), CT/MR...

متن کامل

Fabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System

  Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJR. American journal of roentgenology

دوره 194 6  شماره 

صفحات  -

تاریخ انتشار 2010