Quantification of coronary microvascular resistance using angiographic images for volumetric blood flow measurement: in vivo validation.
نویسندگان
چکیده
Structural coronary microcirculation abnormalities are important prognostic determinants in clinical settings. However, an assessment of microvascular resistance (MR) requires a velocity wire. A first-pass distribution analysis technique to measure volumetric blood flow has been previously validated. The aim of this study was the in vivo validation of the MR measurement technique using first-pass distribution analysis. Twelve anesthetized swine were instrumented with a transit-time ultrasound flow probe on the proximal segment of the left anterior descending coronary artery (LAD). Microspheres were injected into the LAD to create a model of microvascular dysfunction. Adenosine (400 μg·kg(-1)·min(-1)) was used to produce maximum hyperemia. A region of interest in the LAD arterial bed was drawn to generate time-density curves using angiographic images. Volumetric blood flow measurements (Q(a)) were made using a time-density curve and the assumption that blood was momentarily replaced with contrast agent during the injection. Blood flow from the flow probe (Q(p)), coronary pressure (P(a)), and right atrium pressure (P(v)) were continuously recorded. Flow probe-based normalized MR (NMR(p)) and angiography-based normalized MR (NMR(a)) were calculated using Q(p) and Q(a), respectively. In 258 measurements, Q(a) showed a strong correlation with the gold standard Q(p) (Q(a) = 0.90 Q(p) + 6.6 ml/min, r(2) = 0.91, P < 0.0001). NMR(a) correlated linearly with NMR(p) (NMR(a) = 0.90 NMR(p) + 0.02 mmHg·ml(-1)·min(-1), r(2) = 0.91, P < 0.0001). Additionally, the Bland-Altman analysis showed a close agreement between NMR(a) and NMR(p). In conclusion, a technique based on angiographic image data for quantifying NMR was validated using a swine model. This study provides a method to measure NMR without using a velocity wire, which can potentially be used to evaluate microvascular conditions during coronary arteriography.
منابع مشابه
Quantification of absolute coronary flow reserve and relative fractional flow reserve in a swine animal model using angiographic image data.
Coronary flow reserve (CFR) and fractional flow reserve (FFR) are important physiological indexes for coronary disease. The purpose of this study was to validate the CFR and FFR measurement techniques using only angiographic image data. Fifteen swine were instrumented with an ultrasound flow probe on the left anterior descending artery (LAD). Microspheres were gradually injected into the LAD to...
متن کاملMyocardial resistance assessed by guidewire-based pressure-temperature measurement: in vitro validation.
By injecting a few cubic centimeters of saline into the coronary artery and using thermodilution principles, mean transit time (T(mn)) of the injectate can be calculated and is inversely proportional to coronary blood flow. Because microvascular resistance equals distal coronary pressure (P(d)) divided by myocardial flow, the product P(d). T(mn) provides an index of myocardial resistance (IMR)....
متن کاملAssessment of coronary microcirculation in a swine animal model.
Coronary microvascular dysfunction has important prognostic implications. Several hemodynamic indexes, such as coronary flow reserve (CFR), microvascular resistance, and zero-flow pressure (P(zf)), were used to establish the most reliable index to assess coronary microcirculation. Fifteen swine were instrumented with a flow probe, and a pressure wire was advanced into the distal left anterior d...
متن کاملGadolinium-Free Cardiac MR Stress T1-Mapping to Distinguish Epicardial From Microvascular Coronary Disease
BACKGROUND Novel cardiac magnetic resonance (CMR) stress T1 mapping can detect ischemia and myocardial blood volume changes without contrast agents and may be a more comprehensive ischemia biomarker than myocardial blood flow. OBJECTIVES This study describes the performance of the first prospective validation of stress T1 mapping against invasive coronary measurements for detecting obstructiv...
متن کاملQuantification of coronary artery lumen volume by digital angiography: in vivo validation.
BACKGROUND Coronary artery lumen volume may potentially have several advantages over the commonly used variables, such as percent stenosis or minimal lumen diameter, in the assessment of coronary artery disease. The goal of this study is to validate a quantitative assessment of lumen volume using a video densitometry technique. METHODS AND RESULTS Coronary arteriography was performed in 9 swi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- American journal of physiology. Heart and circulatory physiology
دوره 300 6 شماره
صفحات -
تاریخ انتشار 2011