A comparison of the Glidescope® to the McGrath® videolaryngoscope in patients
نویسندگان
چکیده
BACKGROUND The Glidescope® videolaryngoscope is a new device for tracheal intubation that provides an improved view of the larynx. This study was performed to compare the Glidescope with the McGrath videolaryngoscope in terms of time to intubation (TTI) and number of attempts. METHODS Patients were randomly allocated to one of two groups, Glidescope or McGrath group, by using computer-generated numbers. Tracheal intubation was attempted by an anesthesiologist with extensive experience using these two devices. The operator recorded ease of visualization of glottic structures based on the classification described by Cormack and Lehane. Number of failures, number of attempts and their duration, total intubation time, and events during the whole procedure were recorded. The duration of one attempt was defined as the time elapsed between picking up the endotracheal tube and verification of tracheal intubation with visualization of three expiratory carbon dioxide waveforms. TTI was defined as the sum of the duration of all intubation attempts (as many as three), excluding preoxygenation procedures. RESULTS TTI was significantly shorter for the Glidescope® compared to the McGrath® laryngoscope (40.5 vs. 53.3 s, respectively, P < 0.05). However, glottic views obtained at intubation were similar between the two groups. Number of intubation attempts was not significantly different between the two groups (1.03 ± 0.19 vs 1.10 ± 0.32, respectively) (mean ± SD). CONCLUSIONS Study results demonstrated that the Glidescope reduced total intubation time in comparison with the McGrath, in terms of TTI in patients with normal airways.
منابع مشابه
Comparison of Efficacy and Safety of Two Different Enoxaparin Products in Prevention of Venous Thromboembolism Following Major Obstetric-gynecological Surgeries: An Open-label Randomized Clinical Trial
Venous thromboembolism (VTE) occurs in about 5 percent of patients undergoing major abdominal surgeries. Prophylaxis of VTE is recommended using unfractionated heparin (UF) or low molecular weight heparin (LMWH) in high-risk patients. In spite of advantages and confirmed cost-effectiveness of LMWH, high costs of enoxaparin branded preparations limit its use. We aimed to compare the efficacy and...
متن کاملComparison of Efficacy and Safety of Two Different Enoxaparin Products in Prevention of Venous Thromboembolism Following Major Obstetric-gynecological Surgeries: An Open-label Randomized Clinical Trial
Venous thromboembolism (VTE) occurs in about 5 percent of patients undergoing major abdominal surgeries. Prophylaxis of VTE is recommended using unfractionated heparin (UF) or low molecular weight heparin (LMWH) in high-risk patients. In spite of advantages and confirmed cost-effectiveness of LMWH, high costs of enoxaparin branded preparations limit its use. We aimed to compare the efficacy and...
متن کاملSoft Palate Injuries During Orotracheal Intubation With the Videolaryngoscope.
OBJECTIVE The videolaryngoscope has gained popularity for providing superior visualization in intubations. A rare complication of this technology is soft palate injury. Through a literature review and case series, we highlight the risks associated with the Glidescope and McGrath videolaryngoscopes and the management of soft palate injuries. METHOD A case series of multi-institutional review o...
متن کاملEffect of gastric lavage with Hemostasis Powder® on upper gastrointestinal bleeding (Conversion of emergency endoscopy to elective endoscopy)
Background: Gastric lavage has been one of the pillars of the classic treatment for upper gastrointestinal bleeding (UGIB) for many years. The present study investigated effect of gastric lavage with hemostatic powder on complications of UGIB. Methods: This clinical trial study was performed on 54 patients who referred to the emergency department during the year 2017-2018. The subjects were di...
متن کاملRecover burn ointment for managing acute radiodermatitis in patients with breast cancer: A double blind randomized controlled trial
Background: Radiodermatitis is the most common complication of radiotherapy. There is no gold standard for managing the radiodermatitis. This study aimed to evaluate the effect of topical Recove® burn ointment; basically compounded of sesame oil, camphor, and zinc oxide; in preventing acute radiodermatitis. Methods: This double blind RCT (IRCT No.: 201204047136N2) was performed on 71 patients ...
متن کامل