Limitations using the vacuum-assist venous drainage technique during cardiopulmonary bypass procedures.
نویسندگان
چکیده
Vacuum-assist venous drainage (VAVD) can increase venous blood return during cardiopulmonary bypass (CPB) procedures. However, the negative pressure created in the closed cardiotomy reservoir can be transmitted to the oxygenator if a nonocclusive or centrifugal arterial pump is used, resulting in bubble transgression (BT) from the gas to blood compartment of the oxygenator. We analyzed the vacuum pressure required to produce BT using an in vitro circuit including successively a closed reservoir, a pump (centrifugal or roller), and an oxygenator. A constant hydrostatic pressure was maintained onto the oxygenator. Vacuum was applied on the cardiotomy reservoir, progressively increasing negative pressure from 0 to -80 mmHg and monitoring BT with a bubble detector. Six different oxygenators were compared. A partially occlusive roller pump and a centrifugal pump were compared to a control, which was without any pump. A mean negative pressure of -53 +/- 7 mmHg was necessary to produce BT in all the oxygenators in the absence of a pump. The presence of a centrifugal pump between the reservoir and the oxygenator significantly increased the negative pressure required to produce BT compared to the control (-67 +/- 7 mmHg, p < .05). No bubbles were detected using the roller pump (> -80 mmHg needed for BT), thus statistically significant when compared to the centrifugal pump (p < .05). The centrifugal pump offers significant resistance to BT but not as much compared to the roller pump, though BT cannot be prevented if the pump is turned off while the vacuum remains on the reservoir. Therefore, VAVD is a safe technique as long as the perfusionist stops the vacuum when the arterial pump is no longer in use.
منابع مشابه
eComment: Rationalizing the use of assisted venous drainage during minimally invasive valve surgery.
Nomenclature Historical Pages-1.80 m , AVD is unlikely to be required, and, therefore, 2 should not be routinely included in the CPB circuit unless required intraoperatively. This rationale would also have cost-saving implications. Our study also suffers a number of limitations. First, despite all data being prospectively recorded, it has been analysed retrospectively. Second, the patients were...
متن کاملVacuum-assisted venous drainage and gaseous microemboli in cardiopulmonary bypass.
When conventional gravity siphon venous drainage cannot achieve satisfactory venous drainage during minimally invasive cardiac and neonatal surgeries, assisted venous drainage techniques are needed to ensure adequate flow. One assisted venous drainage technique, vacuum-assisted venous drainage (VAVD), the aid of a vacuum in the venous reservoir, is now widely used to augment venous drainage dur...
متن کاملExperimental use of an ultra-low prime neonatal cardiopulmonary bypass circuit utilizing vacuum-assisted venous drainage.
In adult cardiopulmonary bypass surgery, vacuum assisted venous drainage has become a popular technique to augment venous return to the bypass circuit. The application of this technique in neonatal cardiopulmonary bypass surgery could be beneficial to the further miniaturization of neonatal circuitry by coupling radical respositioning of the oxygenator and pump console with decreasing line leng...
متن کاملVacuum-assisted venous drainage in cardiopulmonary bypass and need of blood transfusion: experience of service.
OBJECTIVE To report the experience with the vacuum-assisted venous drainage (VAVD) technique in cardiopulmonary bypass (CPBP) and blood transfusion need. METHODS A retrospective study was made about data from 111 patients who were operated, using VAVD between October 2006 and February 2008, at the Esperança Hospital, Recife, Pernambuco. The necessity of blood transfusion was verified on the s...
متن کاملCan vacuum assisted venous drainage be achieved using a roller pump in an emergency? A pilot study using neonatal circuitry.
There has been much advancement in perfusion technology over its 50 years of progression. One of these techniques is vacuum-assisted venous drainage (VAVD). Many perfusionists augment venous drainage using VAVD, typically from a wall vacuum source. This study explores alternates to providing VAVD if the wall vacuum fails. In two porcine laboratories, approximately 36 in. of 3/16-in. tubing was ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The journal of extra-corporeal technology
دوره 35 3 شماره
صفحات -
تاریخ انتشار 2003