Separation of positional isomers of oligosaccharides and glycopeptides by high-performance anion-exchange chromatography with pulsed amperometric detection.
نویسندگان
چکیده
High-performance anion-exchange (HPAE) chromatography under alkaline conditions (pH congruent to 13) has been found to efficiently separate neutral oligosaccharides (triose to undecaose) according to molecular size, sugar composition, and linkage of monosaccharide units. The method was able to resolve 1----3, 1----4, and 1----6 positional isomers of neutral oligosaccharides, which are defined as having the same number, type, sequence, and anomeric configurations of monosaccharides but differing in the linkage position of a single sugar. From correlating structural features of different oligosaccharides and retention times, we deduced that at least two factors are operative to determine the superior resolution of oligosaccharides by this type of chromatography: (i) the relative acidities of the hydroxyl groups and (ii) the accessibility of oxyanions of the oligosaccharides to the functional groups of the stationary phase. Splitting of peaks attributable to mutarotation was not observed. Reducing oligosaccharides were much more retained than their reduced counterparts. Linkage of Fuc(alpha 1-3) to GlcNAc of oligosaccharides markedly decreased retention times. Positional isomers of two branched monosaccharides, which differed by 1----6 and 1----4 linkages, were widely separated. The separation of 1----3 and 1----4 positional isomers of both tetrasaccharides and glycopeptides containing undecasaccharides demonstrated the significant improvement in resolution of HPAE compared to previous chromatographic methods by either reverse-phase or amine-bonded stationary phases. Picomole quantities of underivatized oligosaccharides have been detected by triple-pulse amperometric detection, which produced similar responses for a wide range of structures. Quantification of two triantennary glycopeptides from bovine fetuin by using either detector response or 1H NMR was comparable. The N-glycanase-catalyzed release of two 1----4 and 1----3 positional isomers of an undecasaccharide from a tryptic glycopeptide of bovine fetuin could be observed and quantified by direct injection of the enzyme mixture into the chromatograph.
منابع مشابه
Simultaneous Separation and Quantification of Linear Xylo- and Cello-Oligosaccharides Mixtures in Lignocellulosics Processing Products on High- Performance Anion-Exchange Chromatography Coupled with Pulsed Amperometric Detection
A simple one-step method was developed for rapid separation and quantification of the linear xylo-oligosaccharides (XOS) and cellooligosaccharides (COS) mixtures by using high-performance anionexchange chromatography coupled with pulsed amperometric detection (HPAEC-PAD). By exploiting small ion-exchange behavioral differences of various oligosaccharide components on the CarboPac PA200 column, ...
متن کاملAnalysis of Carbohydrates by High-Performance Anion-Exchange Chromatography with Pulsed Amperometric Detection (HPAE-PAD)
Anion-Exchange Chromatography I. Mechanism of Separation Although anion-exchange chromatography has been used extensively to analyze acidic carbohydrates and glycopeptides, it has not been commonly used for analysis of neutral sugars. However, examination of the pKa values of the neutral monosaccharides listed in Table 1 shows that carbohydrates are in fact weak acids. At high pH, they are at l...
متن کاملDetermination of mono- and disaccharides in milk and milk products by high-performance anion-exchange chromatography with pulsed amperometric detection
A simple and sensitive liquid chromatographic method for the separation and quantification of monoand disaccharides in rawand processed-milk is described. Samples of cows’, buffalos’, sheeps’ and goats’ milk were analyzed upon clarification and appropriate dilution for the quantification of lactose, galactose, glucose and N-acetylglucosamine (GlcNAc). The separation was accomplished by high-per...
متن کاملDetermination of saccharides in atmospheric aerosol using anion-exchange high-performance liquid chromatography and pulsed-amperometric detection.
An improved method is described for the quantification of primary sugars, sugar alcohols and anhydrosugars in atmospheric aerosols, making use of separation by high-performance anion-exchange chromatography (HPAEC) with pulsed amperometric detection (PAD). Quartz fibre filters from high-volume samplers were extracted with water and the extract injected directly. Repeatability is typically 4% RS...
متن کاملHigh-pressure liquid chromatography of sialic acids on a pellicular resin anion-exchange column with pulsed amperometric detection: a comparison with six other systems.
A wide variety of different sialic acids have been reported in nature. Following their release and purification, detection and quantitation of these molecules is now possible by a number of techniques. We and others have previously reported high-pressure liquid chromatography separation of sialic acids with several different columns, elution methods, and detection techniques. We report here a n...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Proceedings of the National Academy of Sciences of the United States of America
دوره 85 10 شماره
صفحات -
تاریخ انتشار 1988