Self-priming hemodynamic reservoir and inline flow meter for a cardiopulmonary bypass simulation.

نویسندگان

  • David Raasch
  • Jon Austin
  • Richard Tallman
چکیده

Simulator exercises are used at Midwestern University to augment academic and laboratory training toward consolidating particular skills, increasing situation awareness, and preparing the student for practice within the team environment of an operating room. This paper describes an enhanced cardiopulmonary bypass simulator consisting of a self-priming hemodynamic reservoir that includes an inline flow meter. A typical cardiopulmonary bypass adult perfusion circuit was assembled using a roller pump console and integrated oxygenator/heat exchanger/reservoir and primed with 2 liters of water. For patient simulation, a soft-sided reservoir bag was mounted onto an inclined platform. A 1-liter soft-sided bag was placed just above the reservoir, providing an overflow reservoir. The priming line extended to the head of the mannequin. The arterial, venous, and suction lines extended through the open chest. The primed perfusion circuit was connected to ports on the filled reservoir bag. To test the patient simulation, the arterial pump output was adjusted to flow rates ranging from 1-7 liters per minute, with a complete interruption (to zero flow) between each test run. An inline flow meter was added to the bypass circuit and an analog to digital converter board was used to pass flow data into the computer-based simulation program. The use of an inclined hemodynamic reservoir bag proved to be self-priming and functional without problems over a wide range of flows tested. By including a reservoir with the mannequin, plus processing and displaying real-time flow data using the CPB-Sim simulation program, a higher fidelity and more realistic simulation experience was created.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rat cardiopulmonary bypass model: application of a miniature extracorporeal circuit composed of asanguinous prime.

A clinically relevant rat cardiopulmonary bypass (CPB) model would be a valuable tool for investigating pathophysiological and therapeutic strategies on bypass. Previous rat CPB models have been described in the literature; however, they have many limitations, including large circuit surface area, the inability to achieve full bypass, and donor blood requirements for prime. Therefore, we have e...

متن کامل

Virtual patient simulator for the perfusion resource management drill.

Perfusionists require a detailed understanding of a patient's physiological status while comprehending the mechanics and engineering of the cardiopulmonary bypass system, so it is beneficial for them to obtain relevant practical skills using extracorporeal circulation technology and educational physiological simulators. We designed a perfusion simulator system (ECCSIM: Extracorporeal Circulatio...

متن کامل

A low priming volume oxygenator for bloodless priming in cardiopulmonary bypass.

The oxygenator described here arose out of the need to dispense with homologous blood in animal perfusions. It was considered that this could best be attained with an oxygenator having a priming volume sufficiently small to allow the use of isotonic solutions without undue dilution and consistent with full gas exchange and adequate temperature control. It was recognized that modifications to ex...

متن کامل

The Effect of Zero Balance Ultrafiltration of Priming Blood on Clinical Outcomes of Infants Undergo Cardiopulmonary Bypass

Introduction: Pediatric Cardiopulmonary Bypass (CPB) circuit invariably requires priming with Packed Red Blood Cells (PRBCs). Metabolic composition of stored PRBCs is unphysiological. Commencement of PRBC primed CPB leads to rapid transfusion of massive metabolic load. This predisposes pediatric patients to the risk of complications such as electrolyte disturbances, citrate toxicity, acidosis a...

متن کامل

Retrograde autologous priming in cardiopulmonary bypass in adult patients: effects on blood transfusion and hemodilution.

INTRODUCTION Retrograde autologous priming (RAP) is a cardiopulmonary bypass (CPB) method, at low cost. Previous studies have shown that this method reduces hemodilution and blood transfusions needs through increased intra-operative hematocrit. OBJECTIVE To evaluate RAP method, in relation to standard CPB (crystalloid priming), in adult patients. METHODS Sixty-two patients were randomly all...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of extra-corporeal technology

دوره 42 2  شماره 

صفحات  -

تاریخ انتشار 2010