The Indian Basket Trick: a case of delayed paraplegia with complete recovery, caused by misplaced thoracic pedicle screw

نویسندگان

  • Antonin Leroy
  • Reda Kabbaj
  • Arnaud Dubory
  • Manon Bachy
  • Anne-Isabelle Vermersch
  • Raphaël Vialle
چکیده

INTRODUCTION Pedicle screw fixation allows purchase of all three spinal columns without encroaching into the spinal canal improving fracture fixation, as well as deformity correction. Fortunately, neurologic injury associated with pedicle screw malposition is rare. CASE PRESENTATION A 19-year-old boy was surgically treated for severe right thoracic scoliosis associated with a Chiari Type 1 malformation and a C6 to T7 syringomyelia. Six months after the initial surgery, the patient was referred to our institution after three weeks of gait disturbances and repeated falls. Imaging showed the gross misplacement of the left T5 pedicle screw, which crossed the center of the vertebral canal. The initial surgery used a freehand technique of pedicle screw insertion, with anteroposterior and lateral postoperative X-ray control. During the surgery, no SEP modifications were noted during pedicle screw placement. However, after insertion of the second rod and scoliosis correction by posterior translation technique, SEP responses decreased considerably. Revision surgery was performed to remove the misplaced screw. During the first three months after screw removal, repeated clinical examinations showed progressive recovery of the neurological deficits. Gait and bladder functions were normal six months after screw removal, and clinical signs of spasticity disappeared. SEP explorations performed at final follow-up showed similar responses to those performed before the initial surgery for scoliosis correction. DISCUSSION AND EVALUATION Neurologic injury associated with pedicle screw malposition is rare. In early or delayed neurological status worsening, intraoperative or postoperative imaging must be done to detect pedicle screw misplacement. In the current case, thanks to cobalt-chromium and titanium use, MRI and CT scan allowed good visualization of the spinal canal and spinal cord. Experimental studies have shown that neurophysiological monitoring of the spinal cord does not detect moderate compression. In that way, neurophysiological monitoring is an all-or-nothing technique which can misdiagnose early stage of spinal cord injuries. Major penetration of the spinal canal by pedicle screw may conduct to hardware removal. CONCLUSIONS In early or delayed neurological status worsening, intraoperative or postoperative imaging must be done to detect pedicle screw misplacement. In the current case, thanks to cobalt-chromium and titanium use, MRI and CT scan allowed good visualization of the spinal canal and spinal cord. Major penetration of the spinal canal by pedicle screw may conduct to hardware removal.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An endovascular treatment of a thoracic aortic injury caused by a misplaced pedicle screw: Case report and review of the literature.

Aortic injuries are devastating complications after spinal surgery. We here would like to share our experience with a successful endovascular treatment of an iatrogenic thoracic aortic injury caused by misplaced pedicle screw after spinal surgery. A patient underwent posterior spinal surgery for L1 burst fracture was transferred to our department for instrumentation removal. An iatrogenic thora...

متن کامل

Cardiopulmonary Resuscitation-induced Thoracic Vertebral Fracture: A Case Report

Thoracic vertebral fractures are very unusual complications of cardiopulmonary resuscitation (CPR). A 78-year-old man developed cardiac arrest after aspirating and conventional CPR was performed. After recovery, the patient had complete paraplegia (Frankel grade A). Magnetic resonance image of spine showed a dislocation fracture with hematoma at T6 thoracic level. Computed tomography scan of ch...

متن کامل

Hybrid Stabilization of Thoracic Spine Fractures with Sublaminar Bands and Transpedicular Screws: Description of a Surgical Alternative and Review of the Literature

Stabilization of unstable thoracic fractures with transpedicular screws is widely accepted. However, placement of transpedicular screws can cause complications, particularly in the thoracic spine with physiologically small pedicles. Hybrid stabilization, a combination of sublaminar bands and pedicle screws, might reduce the rate of misplaced screws and can be helpful in special anatomic circums...

متن کامل

Surgical technique. Technical notes on reduction of thoracic spine fracture dislocation.

spine is a rare spinal injury often resulting from high-energy trauma. Associated soft-tissue thoracic injuries are common and are compounded by the often-associated paraplegia. Exceptionally, there are some cases of thoracic spine dislocations without neurological injuries. A major challenge in the surgical management of such spinal fractures is achieving reduction and then maintaining it afte...

متن کامل

Accuracy Assessment of Freehand Pedicular Screw Placement

Background: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion withoutthe use of fluoroscopy.Methods: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion.The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvicf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2016