OBJECTIVE The objective of this study was to evaluate the feasibility of using multishot PROPELLER for diffusion-weighted imaging (DWI) of the abdomen. MATERIALS AND METHODS Diffusion-weighted abdominal imaging was performed in 9 healthy volunteers and 3 patients using both single-shot DW-SE-EPI and multishot DW-PROPELLER (BLADE sequence). We compared ADC measurements in phantoms, liver and pancreatic tissues and performed qualitative comparisons of the diffusion-weighted images and ADC maps provided by these 2 techniques. RESULTS DW-PROPELLER significantly improved image quality (P < 0.05) with reduced geometric distortion and artifact. The ADC values of phantoms and abdominal organs measured by DW-PROPELLER were generally greater than those measured by single-shot DW-SE-EPI. The ADC values measured by both DWI techniques were significantly different for liver tissues but not for pancreatic tissues (P < 0.05). Preliminary patient studies demonstrated clearly distinguished lesion areas from surrounding normal liver tissues in the DW-PROPELLER images. DW-PROPELLER offers the potential for high-resolution DWI of the abdomen. CONCLUSIONS The multishot DW-PROPELLER sequence is a promising technique for DWI of abdominal organs. Future clinical studies will evaluate the use of DW-PROPELLER technique for abdominal oncologic imaging applications.
منابع مشابه
3T MR imaging of postoperative recurrent middle ear cholesteatomas: value of periodically rotated overlapping parallel lines with enhanced reconstruction diffusion-weighted MR imaging.
BACKGROUND AND PURPOSE MR diagnostic of postoperative recurrent cholesteatomas is difficult. Our purpose was to compare multishot fast spin-echo periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) diffusion-weighted MR imaging (DWI) with array spatial sensitivity encoding technique (ASSET) single-shot echo-planar DWI and late postgadolinium T1-weighted MR im...
متن کاملHigh-resolution diffusion-weighted imaging with interleaved variable-density spiral acquisitions.
PURPOSE To develop a multishot magnetic resonance imaging (MRI) pulse sequence and reconstruction algorithm for diffusion-weighted imaging (DWI) in the brain with submillimeter in-plane resolution. MATERIALS AND METHODS A self-navigated multishot acquisition technique based on variable-density spiral k-space trajectory design was implemented on clinical MRI scanners. The image reconstruction ...
متن کاملDepiction of the cranial nerves within the brain stem with use of PROPELLER multishot diffusion-weighted imaging.
Despite the recent progress of MR imaging, visualization of the cranial nerves within the brain stem has not been accomplished. Periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) multishot diffusion-weighted imaging, an effective method for compensating for motion and distortion, offers high-quality diffusion-weighted images. We succeeded in depicting the c...
متن کاملDynamic Contrast Magnetic Resonance Imaging (DCE-MRI) and Diffusion Weighted MR Imaging (DWI) for Differentiation between Benign and Malignant Salivary Gland Tumors
Background: Salivary gland tumors form nearly 3% of head and neck tumors. Due to their large histological variety and vicinity to facial nerves, pre-operative diagnosis and differentiation of benign and malignant parotid tumors are a major challenge for radiologists. Objective: The majority of these tumors are benign; however, sometimes they tend to transform into a malignant form. Functional M...
متن کاملFunctional magnetic resonance imaging using PROPELLER-EPI.
Periodically rotated overlapping parallel lines with enhanced reconstruction-echo-planar imaging (PROPELLER-EPI) is a multishot technique that samples k-space by acquisition of narrow blades, which are subsequently rotated until the entire k-space is filled. It has the unique advantage that the center of k-space, and thus the area containing the majority of functional MRI signal changes, is sam...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative radiology
دوره 41 10 شماره
صفحات -
تاریخ انتشار 2006