Range of Motion In High Flexion Total Knee Arthroplasty vs. Standard Posterior Stabilized Total Knee Arthroplasty A Prospective, Randomized Study
نویسنده
چکیده
Range of motion after knee replacement is an important factor in overall outcome. The purpose was to compare motion in patients receiving high flexion prosthesis vs. standard prosthesis. 24 high flexion and standard knee prostheses were used. Patients were followed for two years and evaluated prospectively. The mean HSS was 80.4 for the standard group and 80.7 for the flexion group. At two year follow up the standard prosthesis group had mean flexion of 113°. The high flexion prosthesis group had mean flexion 106°. No knee had aseptic loosening, infection, or osteolysis. At two year follow up, there were no significant differences between groups with regard to range of motion, clinical outcome, or radiographic evaluation.
منابع مشابه
Study of knee range of motion after soft tissue repair in both flexion and extension during total knee arthroplasty: a randomized clinical trial
Background: The patient's position during the recovery time after arthroplasty surgery can be a factor in reducing complications and improving patients’ condition. Therefore, this study was performed to compare the knee range of motion after soft tissue repair in both flexion and extension positions of total knee arthroplasty. Methods: This study is a double-blind clinical trial. The study pop...
متن کاملRe: Comparison of mobile-bearing and fixed-bearing total knee arthroplasty: a prospective randomized study.
The purpose of this prospective randomized study was to compare the postoperative recovery and early results of 2 groups of patients undergoing total knee arthroplasty: 107 patients received an established fixed-bearing posterior-stabilized prosthesis (Legacy Posterior Stabilized [LPS]), and 103 patients the meniscal-bearing prosthesis (Meniscal Bearing Knee [MBK]). Surgical procedures were the...
متن کاملEvaluation of Postoperative Range of Motion and Functional Outcomes after Cruciate-Retaining and Posterior-Stabilized High-Flexion Total Knee Arthroplasty
PURPOSE The purpose of this study was to compare postoperative range of motion and functional outcomes among patients who received high-flexion total knee arthroplasty using cruciate-retaining (CR-Flex) and posterior-stabilized (PS-Flex) type prostheses. MATERIALS AND METHODS Among 127 patients (186 knees) who underwent high-flexion total knee arthroplasty between 2005 and 2007, 92 knees were...
متن کاملMinimum 5-year follow-up results and functional outcome of rotating-platform high-flexion total knee arthroplasty: A prospective study of 701 knees
BACKGROUND To evaluate the midterm clinical outcome, functional outcome, associated complications, and survivorship of high-flexion posterior-stabilized rotating-platform total knee arthroplasty. METHODS We prospectively analyzed 701 knees in 501 patients, who underwent total knee arthroplasty using high-flexion posterior-stabilized rotating-platform prosthesis. Patients were assessed preoper...
متن کاملFlexion and anterior knee pain after high flexion posterior stabilized or cruciate retaining knee replacement.
BACKGROUND Special high-flexion prosthetic designs show a small increase in postoperative flexion compared to standard designs and some papers show increased anterior knee pain with these prosthesis. METHODS A prospective double blind randomized controlled trial investigates the difference in flexion and anterior knee pain between standard and high-flexion total knee arthroplasty. In total 47...
متن کامل